Schumacher 7000A Battery Charger User Manual


 
12
while waiting and will reset if the
engine is not cranked within 5
minutes. (If the charger resets, it sets
itself for a 2A charge and REGULAR
battery.) While waiting for cranking,
the digital display shows the battery
voltage (it can’t be set to percent).
2. Cranking - When cranking is
detected, the charger will automati-
cally deliver up to its maximum
output (at least 70A) as required by
the starting system for up to 8
seconds or until the engine cranking
stops. The digital display shows a
countdown of the remaining crank
time in seconds. It starts at 8 and
counts down to 0.
3. Cool Down - After cranking, the unit
enters a mandatory 2-minute (120
second) cool down state. During this
period, no settings can be changed.
The buttons are ignored. The digital
display indicates the remaining cool
down time in seconds. It starts at 120
and counts down to 0. The 70A
START LED blinks once every
second. During the cool down period,
the charger delivers charge at a rate
of 20A and the CHARGING LED is
lit. After 2 minutes, the 70A START
LED will stop blinking and will light
continuously, indicating that another
crank cycle can be started. The
digital LED will change from display-
ing the countdown back to displaying
the battery voltage.
ENGINE STARTING NOTES:
When the 70A START rate has been
selected, the battery type selected
does not matter and no battery type
LED will be lit.
If the battery is disconnected during
the cool down period, the charger will
reset.
USING YOUR BATTERY CHARGER
OVERVIEW
Using this battery charger is very
simple. First, connect the battery and
AC power following the precautions
listed under “OPERATING INSTRUC-
TIONS”. Then select the appropriate
BATTERY TYPE and CHARGE RATE
for your battery. The charger will then do
everything automatically. This section
explains a few details.
CHARGING: If the charger does not
detect a properly connected battery, the
CHECK (red) LED will light continuously
until such a battery is detected. Charg-
ing will not begin while the CHECK light
is on. When charging begins, the
CHARGING LED will be lit.
AUTOMATIC SHUT OFF: When the 2A
or 20A charge rate is selected, the
charger is set to perform an automatic
charge. When an automatic charge is
performed, the charger stops charging
automatically after the battery is
charged.
ABORTED CHARGE: If charging can’t
be completed normally, charging will be
aborted. When charging is aborted, the
charger’s output is shut off and the red
CHECK LED and digital LED blink on
and off (at opposite times). In that state,
the charger ignores all buttons. To reset
from after an aborted charge, either
disconnect the battery or unplug the
charger.
DESULFATION MODE: If a battery is
left discharged for an extended period, it
could become sulfated and not accept a
normal charge. If the charger detects a
sulfated battery, the charger will switch
to a special mode of operation designed
for such batteries. Activation of the spe-
cial desulfation mode is indicated by
blinking the CHARGING LED. If suc-
cessful, normal charging will resume af-
ter the battery is desulfated. The
CHARGING LED will then stop blinking
and light continuously. Desulfation could
take up to 10 hours. If desulfation fails,
charging will be aborted and the CHECK
(red) LED will blink.