11
USING THE BUILT-IN BATTERY TESTER
OVERVIEW
This battery charger has a built-in battery
tester that displays either an accurate bat-
tery voltage or an estimate of the battery’s
relative charge based on the battery volt-
age and the Battery Council International
scale.
TESTING SEQUENCE
There are four basic steps required to use
the SC-8000A as a battery tester.
1. Connect the charger battery clamps to
the battery. Be sure to follow all of the
precautions listed under “OPERATING
INSTRUCTIONS”.
2. Connect the charger power cord to a 120V
AC 2-prong wall outlet. Again, be sure to
follow all of the precautions listed under
“OPERATING INSTRUCTIONS”.
3. If necessary, press the BATTERY
TYPE button until the correct type is
indicated.
4. Read the voltage on the digital display
or press the DIGITAL DISPLAY button
to set the tester to BATTERY % and
read the battery percent.
TESTER AND CHARGER
When rst turned on, the SC-8000A oper-
ates only as a tester, not as a charger. To
continue to use it as only a tester, avoid
pressing the CHARGE START button. Se-
lecting a charge rate activates the battery
charger and deactivates the tester. Press-
ing the CHARGE START button when the
ENGINE START LED is lit (except during
the 180 second cool down) will shut off the
charger and activate the tester.
POWER-UP IDLE TIME LIMIT
If no button is pressed within 15 minutes
after the SC-8000A is rst powered up,
it will automatically switch from tester
to charger, if a battery is connected. In
that case, the charger will be set for the
SMALL BATTERY and 12V REGULAR
BATTERY type.
TESTER WITHOUT TIME LIMIT
If either the DIGITAL DISPLAY or BAT-
TERY TYPE button is pressed within the
first 15 minutes after the SC-8000A is
powered up, it will remain a tester (not a
charger) indenitely, unless a charge rate
is selected.
TESTING AFTER CHARGING
After the SC-8000A has been changed
from tester to charger (by selecting a
charge rate), it remains a charger. To
change the SC-8000A back to a tester,
press the CHARGE START button until
all CHARGE START or CHARGE RATE
LEDs are off.
TESTER STATUS LEDs
When the SC-8000A is operating as a bat-
tery tester, the status LEDs light under the
following conditions:
• The CHARGED (green) LED will light if
a charged battery is tested.
• The CHARGING (yellow) LED does not
light in the battery test mode.
• The CONNECTED LED lights when a
properly connected battery is detected.
• When the tester digital display is set to
VOLTAGE, the CHARGED and CHARG-
ING LEDs won't light it could be testing
a battery or an alternator.
INITIAL PERCENT CALCULATION
When a battery % is calculated for the rst
time after connecting a battery, the digital
display will show three dashes (“---”) for a
period as long as several seconds while
the tester analyzes the battery.
NOTES FOR TESTING BATTERY %
A recently charged battery could have a
temporarily high voltage due to what is
known as “surface charge”. The voltage
of such a battery will gradually drop during
the period immediately after the charging
system is disengaged. Consequently, the
tester could display inconsistent values
for such a battery. For a more accurate
reading, the surface charge should be
removed by temporarily creating a load on
the battery, such as by turning on lights or
other accessories.
The battery % ranges from 0 to 100.
The battery tester is only designed to test
batteries. Testing a device with a rapidly
changing voltage could yield unexpected
or inaccurate results.