Sears 47006 Battery Charger User Manual


 
8
Sears 006 - Sch 552 11/2/95
Charging Your Battery
Charging your battery in the vehicle:
1. Arrange the power cord and charging leads
carefully in order to avoid damage that could be
caused by the hood, door, or moving engine parts.
2. Keep clear of the fan blades, belts, pulleys, and
other parts that can cause injury.
3. Check the polarity of the battery posts using the
identification marks on the battery case: POSITIVE
(POS, P, +) and NEGATIVE (NEG, N, -).
4. Identify which battery post is ground or connected to
the chassis. THE NEGATIVE POST IS NORMALLY
THE ONE THAT IS GROUNDED.
5. To charge a negative grounded post system:
Connect the red (POSITIVE) charger clamp to the
ungrounded POSITIVE (POS, P, +) post of the
battery. Next, connect the black (NEGATIVE) clamp
to a heavy unpainted metal part of the chassis or
engine block, away from the battery. Do not
connect clamp to carburetor, fuel lines, or sheet
metal parts.
To charge a positive grounded post system:
Connect the black (NEGATIVE) charger clamp to the
ungrounded NEGATIVE (NEG, N, -) post of the
battery. Then connect the red (POSITIVE) clamp to
a heavy unpainted metal part of the chassis or
engine block, away from the battery. Do not con-
nect clamp to carburetor, fuel lines or sheet metal
parts.
6. Connect the clamp to the battery post and twist or
rock back and forth to make a solid connection. This
will help keep the clamps from slipping off the posts
and causing sparks.
7. Set your charger's right-hand 3-position selector
switch to the OFF position. Then plug the charger's
power cord into a grounded AC outlet.
8. Select the desired charge rate. (See "Setting the
Controls" on page 7.)
9. The charger will not stop when the battery is fully
charged. For this reason it is important to check
charging progress frequently. Overcharging can
damage a battery, you must monitor and unplug
charger when battery is fully charged.
10. When the battery is fully charged, the AMMETER
needle will fall to about half the charge rate selected.
For specific positions, see the “Ammeter” section of
“Setting the Controls” on page 7.
11. When the battery is fully charged, unplug the
charger power cord. Next, set the right-hand switch
to the OFF position.
12. Standing away from the battery, remove the charger
clamp from the chassis first, then from the battery
post or terminal.
13. Clean and store the battery charger in a dry location.