Woodstock M1054 Saw User Manual


 
-9-
M1048 10" x 18" Metal Cutting Bandsaw
ELECTRICAL
Operating Voltage Amp Draw Min. Circuit Size Plug/Receptacle Extension Cord
220V Operation 15 Amps 20A NEMA 6-20 12 Gauge
ELECTRICAL
We do not recommend using an extension cord for 220V
operation. When it is necessary to use an extension cord,
use the following guidelines:
Use cords rated for Standard Service
Never exceed a length of 50 feet
Ensure cord has a ground wire and pin
Do not use cords in need of repair
Extension Cords
Grounding
This machine must be grounded! Verify that any exist-
ing electrical outlet and circuit you intend to plug into
is actually grounded. If it is not, it will be necessary to
run a separate copper grounding wire, of the appropri
-
ate size, from the outlet to a known ground. Under no
circumstances should you connect your machine to an
ungrounded power source or electrocution or sever
e
shock could occur.
220V Operation
The Model M1048 is wired for 220V operation. Always
connect this machine to a dedicated circuit (wire, break-
er, plug, receptacle) with a verified ground, using
the
recommended circuit size and plug/receptacle listed at
the bottom of this page.
Never replace a circuit breaker with one of higher amper
-
age without consulting a qualified electrician to ensure
compliance with wiring codes
. If you are unsure about
the wiring codes in your area or plan to connect your
machine to a shared circuit, you may create a fire haz
-
ard—consult a qualified electrician to reduce this risk.
Electrocution or severe shock could
occur if machine is not grounded.
Figure 3. Plug & receptacle examples.
Replacing an existing circuit breaker
with one rated for higher amperage
may result in a fire. Get help from an
electrician if your circuit is too small
for the machine.
6-20P 6-20R