Spectra HL700 Laser Level User Manual


 
A) HL700 is in the laser beam and the
power is on:
Press any switch to return to normal
operation.
The current elevation read-
ing will be held. A flashing
display will confirm the
reading has been captured
.
1 x quick
B) HL700 is out of the laser beam and
power is on:
A short intermittent
beep (The beeper
will turn on to Low if
turned off.)
+
1.
Press any switch to return to normal
operation.
2. Place the HL700 in the beam. (Example:
Fasten it to a measuring rod, bring the
HL700 into the laser beam. You now have
5 seconds to plumb the rod and get the
reading captured.)
The beeper will
chirp rapidly after
approximately 5
seconds to confirm
beam capture. A flashing
display will also indicate
the reading has been
captured
.
+
1 x quick
Special Menu Functions
SENS Sensitivity Medium*-HighLow
AVG Averaging algorithm Medium*High - Low
D.R.O. Numeric display ON*-OFF-.1mm
UNIT Units of measure MM*-CM-IN-FRAC-FT
FRC.R. Fractional Reduction ON*-OFF
ARRW Arrow Display DB*(deadband)-PR (prop.)
O.O.B. Out-of-Beam Display ON*-OFF
GRD.A. Grade Alarm ON-OFF*
A.S.O. Automatic shutoff 0.5h*-24h-OFF
TX.O.L. Transmitter Out-of-Level OFF*RPS
TX.O.B. Transmitter Low Battery OFF*-RPS
INFO Information about the Laserometer
(for 2 Sec., then SENS)
Press switches
together for 2 sec
.
1. Scrolling up or down.
How to change Menu functions:
2. Enter Change mode.
3. Change selected items
.
4. Confirm change.
5. To Exit.
or
+
Change special Menu Functions only in the
case of special job requirements!
Automatic Shutoff
A.S.O. (Automatic Shut Off):
0.5 - After 30 Minutes*
OF - Off (Unit is permanently on.)
24 - 24 hour shutoff.
Out-of-Beam Display
O.O.B. (Out-of-Beam Display):
Sequence to show direction to get back in
the laser beam ( for 25 s)
ON - Out-of-Beam Display ON*
OF - Out-of-Beam Display OFF
Grade Alarm
GRD.A. (Grade Alarm):
When turned ON, disables the audible
signal when on-grade. When moved out
of the on-grade deadband, the beeper
activates as normal:
ON - Alarm on (Solid beeper OFF)
OF - Alarm off (Solid beeper ON)*
* Default setting
For more information about special Menu
Function contact the manu-facturer,
importer or your local dealer
.
Sensitivity of reception
SENS (Sensitivity):
Selects reception sensitivity to laser and
other light sources.
MD - Medium*: for most applications.
HI - High: When laser beam is
weak, or at very long distances.
LO - Low: If outside sources are
disturbing elevation readings
.
Action Display Remarks
Initialization:
1. Test of LCD, LED and beeper
2. CAL: Calibration (3 sec.)
3. Unit is ready for use.
(Do not power up the unit in a laser beam
or strobe. If detected, the unit will display
“E200” and revert to the previous
calibration.)
The selected unit of measure determines
the displayed deadband (accuracy).
The current accuracy is stored in memory
and will be retained when the unit is turned
off or when batteries are replaced.
The current beeper
volume is stored in
memory and will be
retained when the unit is
turned off or when bat-
teries are replaced.
The current unit of measure is stored in
memory and will be retained when the unit
is turned off or when batteries are replaced.
The current brightness of LEDs
is stored in memory and will
be retained when the unit is
turned off or when batteries are
replaced.
Action Display Remarks
Accuracy in mm:
0.5 1.0 2.0 5.0 10.0
Beeper
Loud
Beeper
Medium
Beeper
Low
(No symbol)
mm - cm - in - frac - ft
LEDs
Bright
LEDs
Dim
LEDs
OFF
(No symbol)
1
2
3
Turn power ON/OFF
Press and hold for 2 seconds to turn
power OFF.
Press once to display current setting;
push again to scroll through options.
Press together to cycle the selection.
+
Press once to display current setting,
additional pushes to scroll through options.
Select accuracy
Select beeper volume
Select units of measure
Select brightness of LEDs
CAPTURE Function
Press once to change current setting
(A beep confirms the selected volume.)
Beeper
Off