Spectra QM95 Laser Level User Manual


 
– 21 – – 22 – – 23 –
– 13 – – 14 – – 15 – – 16 –
N324
– 17 – – 18 – – 19 – – 20 –
Settings menu (to change sound and unit of measure)
1) With the tool switched off, press and hold the Power On/Off Button
for approximately 2 seconds to enter menu mode.
2) Press + to cycle sound on or off
3) Press the – button to cycle through unit measure options:
m cm mm
in 1/8 in 1/16 in 1/32 in
ft 1/8 ft 1/16 ft 1/32 ft
yd
4) To close the menu, press and hold the Power On/Off Button for
approximately 2 seconds. The tool is switched off and settings are saved.
Notice to Our European Union Customers
For product recycling instructions and more information,
please go to: www
.trimble.com/environment/summary.html
Recycling in Europe
To recycle Trimble WEEE, call: +31 497 53 2430, and ask for the “WEEE
associate,” or
mail a request for recycling instructions to:
Trimble Europe BV
c/o Menlo Worldwide Logistics
Meerheide 45
5521 DZ Eersel, NL
© 2012, Trimble Navigation Limited. All rights reserved.
Reorder PN 1213-1220 Rev A (09/12)
North-Latin America
Trimble / Spectra Precision Division
8261 State Route 235
Dayton, Ohio 45424-6383
U.S.A.
(888) 527-3771
(Toll Free in U.S.A.)
+1-937-203-4419 Phone
+1-937-482-0030 Fax
www.trimble.com/spectra
Europe
Trimble Kaiserslautern GmbH
Am Sportplatz 5
67661 Kaiserslautern
GERMANY
Tel +49-(0)6301-71 14 14
Fax +49-06301-32213
Africa & Middle East
Trimble Export Middle-East
P.O. Box 17760
JAFZ View, Dubai
UAE
+971-4-881-3005 Phone
+971-4-881-3007 Fax
Asia-Pacific
Trimble Navigation Singapore PTE Ltd.
80 Marine Parade Road, #22-06
Parkway Parade
Singapore, 449269
+65 6348 2212 Phone
+65 6348 2232 Fax
China
Trimble Beijing
Room 2805-07, Tengda Plaza,
No. 168 Xiwai Street
Haidian District
Beijing, China 100044
+86 10 8857 7575 Phone
+86 10 8857 7161 Fax
www.trimble.com.cn
Service Request
To locate your local dealer or authorized Trimble Service Center outside
the U.S.A. for service, accessories, or spare parts, contact one of our
offices listed below.
Warranty
Trimble warrants the Quick Measure QM95 to be free of defects in
material and workmanship for a period of 3 years. For the first 2 years,
Trimble or its authorized Dealer or Service Center will repair or replace,
at its option, any defective part, or the entire product, for which notice
has been given during the warranty period. For the 3rd year, an
exchange fee may apply. This warranty period is in effect from the date
the system is delivered by Trimble or its authorized Dealer to the
purchaser, or is put into service by a Dealer as a demonstrator or rental
component.
Any evidence of negligent or abnormal use, or any attempt to repair
equipment by other than factory-authorized personnel or Trimble
certified or recommended parts, automatically voids the warranty.
The foregoing states the entire liability of Trimble regarding the
purchase and use of its equipment. Trimble will not be held responsible
for any consequential loss or damage of any kind.
This warranty is in lieu of all other warranties, except as set forth above,
including an implied warranty. Merchantability of fitness for a
particular purpose is hereby disclaimed.
Customers should send products to the nearest authorized Factory,
Dealer or Service Center for warranty repairs, freight prepaid. In
countries with Trimble Service Subsidiary Centers, the repaired products
will be returned to the customer, freight prepaid.
Declarations
We declare, on our sole responsibility, that this product complies with
the following directives and standards:
EN 50081-1, EN 61000-6-2, 2004/108/EC.
Designation: Laser range meter
Type: QM95
Laser Safety
Use of this product by people other than those trained on this product
may result in exposure to hazardous laser light.
• Do not remove warning labels from the unit.
• The QM95 is a Class 2M (635 nm) laser product .
• Never look into the laser beam or direct it to the eyes of other people.
• Always operate the unit in a way that prevents the beam from getting
into people‘s eyes.
Specifications
Measuring Range* 0.1 to 200 m (1 to 650 ft)
Accuracy ± 1.0 mm typical (± 1/24 in)
Functions Individual measure, Continuous measure
Area, Addition, Subtraction
Measure reference Front, Rear, Rear with Extension tab
Automatic shut o Laser - 1 minutes / Product - 10 minutes
Battery life (alkaline) 8000 measures
Operating temperature -15⁰C to +50⁰C (3⁰F to 122⁰F)
Storage temperature -25⁰C to +65⁰C (-13⁰F to 149⁰F)
Power supply 2 x AA x 1.5V
Power indication LCD 4 segments - 100%, 75% 50%, 25%
Laser Safety Class II as per EN 60825-1:2007;
IEC 60825-1:2007 CFR 21 § 1040 (FDA)
Laser Type / Power 635 nm visible red / < 1.0 mW
Dimensions 62 x 28.5 x 120 mm (2.4" x 1.2" x 4.7")
Weight 217 g (7.7 oz) with batteries
Dust & Water resistance IP54
Drop Performance 1.5 m (5 ft)
* Dependent upon several factors. See table next page
General Operation
Addition and Subtraction
+ The next measure is added to the previous one
- The next measure is subtracted from the previous one
Clear button
Press the C button to clear the last reading. During area measures, the
C button clears the most recent measure, but preserves previous
measures.
MENU
m
Measurement
range on
standard
target
Albedo Temp. Light Range
>5 -10⁰C to +50⁰C <1000 lx 0.17 to 200 m
1 +10⁰C to +35⁰C <1000 lx 0.17 to 120 m
0.2 +10⁰C to +35⁰C <1000 lx 0.17 to 55 m
0.2 -10⁰C to +50⁰C <1000 lx 0.17 to 50 m
1 +10⁰C to +35⁰C 100000 lx 0.17 to 50 m
0.2 +10⁰C to +35⁰C 100000 lx 0.17 to 50 m
1 -10⁰C to +50⁰C 100000 lx 0.17 to 45 m
0.2 -10⁰C to +50⁰C 100000 lx 0.17 to 45 m
Minimum measuring distance 170 mm
Clearness >300 m
Measurement range:
Distance performance and measure speed is dependent upon several
factors:
Ambient lighting
Target reflectivity
Dust and particles in the air
Temperature
General Care, Safety And Storage
General safety rules
a) Check the condition of the tool before use.
b) The user must check the accuracy of the tool after it has been
dropped or subjected to other mechanical stresses.
c) Although the tool is designed for the tough conditions of jobsite use,
as with other measuring instruments it should be treated with care.
Do not use prisms or mirrored surfaces
Distances can be measured from all stationary targets without a highly
reflective surface, i.e. concrete, stone, wood, plastic, paper, etc. The use
of prisms or other highly reflective targets is not permissible and, if
attempted, may falsify the results.
Calibration Check
It is recommended to occasionally check the calibration of the tool.
1) Select a known measure distance about 1 to 5 meters (3 to 15 ft) that
does not change over time.
2.) Measure the distance 10 times. Calculate the mean deviation from
the actual distance. The measured mean deviation should be less than
the typical accuracy tolerance of
± 1.5 mm (± 1/16 in)
Cleaning and drying
1. Blow dust off the lens.
2. Do not touch the lens with the fingers.
3. Use only a clean, soft cloth for cleaning. If necessary, moisten the
cloth slightly with pure alcohol or a little water.
NOTE
Do not use any other liquids as these may damage the plastic
components.
Storage
The temperature limits for storage of your equipment must be observed,
especially in winter / summer.
Remove the tool from its pouch if it has become wet. The tool, its
carrying case and accessories should be cleaned and dried (at maximum
40°C). Repack the equipment only once it is completely dry. Check the
accuracy of the equipment before it is used after a long period of storage
or transportation.
Transport
Use the original packaging or packaging of equivalent quality for
transporting or shipping your equipment.
CAUTION
Always remove the batteries before shipping the tool.
Trouble Shooting
Fault Possible cause Remedy
e unit can’t be switched on. e batteries are exhausted. Replace the batteries.
Incorrect battery polarity. Insert the batteries correctly and close the battery
compartment cover.
e button is faulty. Contact Service
No distances displayed by the unit. Measure Button was not pressed. Press the Measure Button.
Unit was not switched on Press the Measure Button.
Faulty display. Contact Service
Frequent error messages or the unit doesn’t
measure.
e target surface is too brightly lit by the sun. Measure from the other direction – sun from behind.
e target surface is too shiny. Take measurements from less shiny surfaces.
e target surface is too dark. Use a lighter colored surface
Bright sunlight towards the tool. Shade the unit.
Temperature indicator - symbol in the display
Temperature too high (>+50 °C / 122 °F) Allow the unit to cool down.
Temperature too low (<-10 °C / 14 °F) Allow the unit to warm up.
Unfavorable signal conditions - symbol in the
display
Insucient reected laser light. Observe the minimum measuring distance (>200
mm / 8 inch from the front edge of the unit);
clean the lenses; take the measurement from a
dierent surface or use a target plate.
General hardware fault - symbol in the display Hardware fault
Switch the unit o and on again.