Bostitch 175869REVA Air Compressor User Manual


 
FEATURES OF THE BOSTITCH CAP2000P-OF
A. Pressure Switch: - The pressure switch is
the activation mechanism that is used to
start and stop the compressor. When the
switch is pulled out to the “On” position, the
motor and pump will compress air until tank
pressure reaches the upper limit of the
factory set operating pressure. When tank
pressure falls below the factory set “cut in”
pressure, the compressor will again
automatically start to compress air.
B. Tank Pressure Gauge: The tank pressure
gauge indicates the air pressure that is
present in the tank in PSI (lbs/sq. in.).
C. Regulated Pressure Gauge: The
regulated pressure gauge indicates the
amount of pressure that is allowed into the
discharge line according to the setting of the
regulator.
D. Regulator Knob: The regulator knob is used to adjust the air pressure that is available at
the discharge line. The discharge air pressure is increased by turning the knob clockwise
and decreased by turning the knob counter clockwise.
E. Drain Cock: Twist style valve that drains moisture from the tank when opened.
7
A
B
C
D
E