-6-
A
B
1. Move pusher to rear until
latched. Cover will open.
Pusher front will drop into
notch on top of magazine
assembly.
2. Drop staple stick over magazine and
slide forward. Repeat until magazine
is loaded, allowing enough space for
pusher to disengage the magazine
and the cover to close.
Approximately 1/2" (13mm)
3. Pull and hold top part of
knob (A) and depress
bottom part of knob (B) in
a clockwise direction to
release pusher.
COVER
CONTACT
ARM
ADJUSTING
NUT
ADAPTER
COVER
MOUNTING
NUTS
NOTE: Use only staples recommended by Bostitch for the 600,700 & 800 Series staplers or staples
which meet Bostitch specifications.
LOADING THE 600,700 & 800
EYE PROTECTION which conforms to ANSI specifications and provides protection against
flying particles both from the FRONT and SIDE should ALWAYS be worn by the operator and
others in the work area when connecting to air supply, loading, operating or servicing this
tool. Eye protection is required to guard against flying fasteners and debris, which could
cause severe eye injury.
The employer and/or user must ensure that proper eye protection is worn. Eye protection
equipment must conform to the requirements of the American National Standards Institute,
ANSI Z87.1 and provide both frontal and side protection. NOTE: Non-side shielded
spectacles and face shields alone do not provide adequate protection.
TO PREVENT ACCIDENTAL INJURIES:
•Never place a hand or any other part of the body in nail discharge area of tool while
the air supply is connected.
• Never point the tool at anyone else.
• Never engage in horseplay.
•Never pull the trigger unless nose is directed at the work.
•Always handle the tool with care.
• Do not pull the trigger or depress the trip mechanism while loading the tool.
Always disconnect air supply: 1. Before making adjustments; 2. When servicing the tool;
3. When clearing a jam; 4. When tool is not in use; 5. When moving to a different work area,
as accidental actuation may occur, possibly causing injury.
“DIAL-A-DEPTH™” FASTENER CONTROL ADJUSTMENT
The DIAL-A-DEPTH™ Fastener Control adjustment feature provides close control of the fastener drive depth;
from flush with the work surface to shallow or deep countersink. First, set the air pressure for consistent drive
in the specific work as described on page 5, then use the DIAL-A-DEPTH™ Fastener Control adjustment to
give the desired depth of drive.
TO ADJUST DIAL-A DEPTH™ FASTENER CONTROL ADJUSTMENT:
1. With air pressure set (refer to Setting the Correct Pressure on (Page 5), drive a few fasteners into a
representative material sample to determine if adjustment is necessary.
2. If adjustment is required, disconnect air supply.
3. Refer to label on outside of door for direction to turn adjusting nut. (See illustration)
4. Remove cover mounting nuts, cover and adapter. Observe the orientation of the flats on the adjusting
nut. Rotate the adjusting nut to the left to increase fastener drive depth, or to the right to decrease it.
Reorientate the flats to be same as before. Reinstall adapter, cover and mounting nuts.
5. Before reconnecting air supply, check that trip mechanism parts operate freely with no binding or sticking.
6. Reconnect air supply.