Once you have safely accessed the cutting chamber, check the current distance between the bed
knives and the rotor knives using a feeler gauge. (See
Figure 9.)
NOTE: The distance set by the manufacturer for normal
application is 0.006”-0.008” (0.15-0.20 mm). If the gap between
the bed knives and the rotor knives is found to be greater than that,
an adjustment must be made. (See Section 6-4: Inspection and
Adjustment of Knives.)
Once you have checked the knife gap, close the hopper, secure it
with the appropriate swing bolt, reinsert the bin, and close the front
panel.