4 STEP CHARGE
STEP 1 - High charge:
STEP 2 - ABSORPTION:
STEP 3 - FLOAT:
STEP 4 - RESET:
During this stage the
charger supplies a
maximum current and
the voltage increases
progressively according
to the battery type
selected. This step
depends on the initial
state of the batteries.
The “Fast Charge” LED
is on.
This is an adjustable
period during which the voltage is kept at its maximum and the current decreases in order to optimise the battery
charge. The “Absorption” LED is on.
The voltage is kept at float level in order to maintain the charge without increasing the temperature of the
batteries. They can be left connected without any damage. The “Float” LED is on.
POWERPACK function: Full current is available for on-board supply.
If the battery voltage goes down below 11.5V/23.0V, then the charge cycle starts all over again with step 1.
FUSE
CHARGERAMPS
PLUS 30%
Installation for 3 battery banks
+
BATTERY TYPE
SELECTOR
+
+
+
+
+
+
LIVE
NEUTRAL
EARTH
POSITIVE
POSITIVE
POSITIVE
NEGATIVE
REMOTE CONTROL
FUSE
FUSE
CHARGERAMPS
PLUS 30%
Fig. 3
English
Auto adjust
3
Cable Size Recommendation:
Charger Output Cable Length 0 - 1.5 mtr 1.5 - 4 mtr
Important: Two 35 sq mm cables in parallel are
equivalent to a single 70 sq mm cable.
25 sq mm
0-25 amps 6 sq mm 10 sq mm
25-45 amps 16 sq mm
45-85 amps 25 sq mm 35 sq mm
85-125 amps 35 sq mm 50 sq mm
125- 180 amps 50 sq mm 70 sq mm
180-330 amps 70 sq mm 90 sq mm
Table 1
Sterling fuseholder
GMFB-4848
(not included)
FUSE
CHARGERAMPS
PLUS 30%
Installation for 1 battery bank
+
BATTERY TYPE
SELECTOR
+
+
+
+
+
+
LIVE
NEUTRAL
EARTH
POSITIVE
POSITIVE
POSITIVE
NEGATIVE
REMOTE CONTROL
FUSE
80-250 v
a/c 40 -60 hz
input
FUSE
CHARGERAMPS
PLUS 30%
Installation for 2 battery banks
+
BATTERY TYPE
SELECTOR
+
+
+
+
+
+
LIVE
NEUTRAL
EARTH
POSITIVE
POSITIVE
POSITIVE
NEGATIVE
REMOTE CONTROL
FUSE
80-250 v
a/c 40 -60 hz
input
FUSE
CHARGERAMPS
PLUS 30%
Progressive battery charging curves