Stow cs403020 Saw User Manual


 
STOW CS4030 SAW • OPERATION MANUAL — REV. #0 (12/13/07) — PAGE 31
/02) — PAGE 31
STOW CS4030 SAW — BATTERY
To install the battery on the saw, make sure that the battery is
properly clamped into the battery box. Connect the positive cable
to the positive terminal on the battery first, then connect the
negative cable to the negative terminal.
Use all safety precautions specified by the battery
manufacturer when working with the battery. See further
specific safety information on page 18 of this manual.
CAUTIONCAUTION
CAUTIONCAUTION
CAUTION
Battery Setup
This saw was shipped with a wet charged battery, (Figure 21).
This battery may need to be charged for a brief period of time as
per the manufacturer instructions.
Figure 21. Battery and Battery Box
NOTE
The STOW CS4030 Saw uses 2
positive battery cables and 2
negative battery cables. One set is
for the starter on the engine and the
other set is for the raise/lower pump
assembly. Make sure that both sets
of cables are connected to the battery.
Battery electrolyte contains corrosive,
toxic chemical. (dilute sulfuric acid).
Avoid contact with eyes and skin.
WARNINGWARNING
WARNINGWARNING
WARNING
Flammable, explosive gas. (produces
hydrogen gas while charging or during
operation). Keep area around battery
well ventilated and keep from any fire
source.
Shock or Fire due to electric short-
circuit. Disconnect battery cables
before inspecting electrical
system and never "spark" battery
terminals to test for charge.
WARNINGWARNING
WARNINGWARNING
WARNING