INSTALLATION
Improper stack up of hardware will cause
excessive heat and fuse failure. Stack up
as shown.
WARNING
+ (red)
EXPLODED VIEW
OF FUSE ASSEMBLY
+
_
Battery Cable Fusing
A fuse is required by the NEC to protect
the battery and cables. A UL Listed DC rated
slow blow fuse must be installed in the positive
(+) battery cable, within 18 inches of the
battery.
Recommended Fuse:
UL Listed Class T
JLLN
with a DC Rating. This fuse with fuse
holder is available from your dealer or Heart
Interface.
FUSE HOLDER
FUSE
BATTERY
CABLE
INVERTER
CABLE
FLAT WASHER
LOCK WASHER
NUT
RING / RING TERMINAL
For Freedom 15 & 15D
200 Amp Fuse & Holder PN# 84-4155-00 (C/R)*
200 Amp Fuse & Holder PN# 84-4158-00 (R/R)**
200 Amp Fuse Only PN# 84-4157-00
For Freedom 20 & 20D
300 Amp Fuse & Holder PN# 84-4156-00 (C/R)*
300 Amp Fuse & Holder PN# 84-4154-00 (R/R)**
300 Amp Fuse Only PN# 84-4151-00