Tripp Lite APSX6048VRNET Welding System User Manual


 
Automatic overload and thermal (overheating) shutoff
Front panel remote control connector enables remote off/on switching (APSRM4 sold separately)
Load sensing control dial enables adjustable load threshold required to automatically turn the inverter on and off in DC mode as load
conditions change
Automatic Generator Starter jack enables user configuration of automatic generator start-up as inverter batteries drop to 23.0 VDC and
generator shutoff as inverter batteries are recharged to 28.2 VDC.
Remote battery temperature sensing connection function prolongs battery life by adjusting the charge float voltage level based on battery
temperature
DB9 communication port for SNMPWEBSOLOHV management.
Specifications
OVERVIEW
Intended
Application
Emergency Power, Remote Power, Alternative Power
OUTPUT
Frequency
compatibility
50 / 60 Hz
Output watts 6000
Continuous output
capacity (watts)
6000
Peak output
capacity (watts)
12000
Output nominal
voltage
208/230V
Output voltage
regulation
LINE POWER (AC): Maintains 208/230V nominal sine wave output from line power source. INVERTER POWER (AC):
Maintains sine wave output voltage of 208/230 VAC (+/-5%).
Output frequency
regulation
50/60 Hz (+/- 0.3 Hz)
Outlet quantity /
type
Hardwire
INPUT
Nominal Input
Voltage(s)
Supported
208V AC; 230V AC
Recommended
Electrical Service
DC INPUT: Requires 48VDC input source capable of delivering 138A for the required duration (when used at full
continuous capacity - DC requirements increase during OverPower and DoubleBoost operation). For automotive
applications, professional hardwire installation with 250A minimum battery system fusing is recommended.
Maximum input
amps / watts
DC INPUT: Full continuous load - 145A at 48VDC. AC INPUT: 30 amps at 208/230VAC with full inverter and charger
load
Input connection
type
DC INPUT: Set of DC bolt-down terminals. AC INPUT: Hardwire via built in terminal strip with cover plate
Voltage
compatibility (VAC)
208; 230
Voltage
compatibility (VDC)
48
BATTERY
Expandable
battery runtime
Runtime is expandable with any number of user supplied wet or gel type batteries