Wagner SprayTech 558023 Paint Sprayer User Manual


 
ProSpray3.29•3.31 9
GB
Starting operation
4
4.2 Control Panel Indicators
The following is a description of the control panel indicators.
Pressure
Indicator
Service
Indicator
Pressure Indicator
The pressure indicator shows the current operating pressure of the
sprayer.Ithasthreedierentindications:blinkingyellow,solid
yellow, and solid green.

When the pressure indicator is blinking yellow, the sprayer is
operating between 0 and 1.4 MPa (14 bar). A blinking yellow
pressureindicatormeans:
• Thesprayerispluggedinandturned“ON”
• Thesprayerisatprimingpressure(littleornopressure)
• Itissafetomovethereliefvalvebetweenpositions
• Itissafetochangeorreplacethespraytip
i
If the pressure indicator begins blinking yellow when
the pressure control knob is set at a higher pressure

the spray tip is worn or the sprayer is in need of
service/repair.

When the pressure indicator is solid yellow, the sprayer is operating
between 1.4 MPa (14 bar) and 12 MPa (120 bar). A solid yellow
pressureindicatormeans:
• Thesprayerisattheproperpressuresettingforsprayingstain,
lacquer, varnish, and multi-colors
Solid Green
When the pressure indicator is solid green, the sprayer is operating
between 12 MPa (120 bar) and 23 MPa (230 bar). A solid green
pressureindicatormeans:
• Thesprayerisattheproperpressuresettingforsprayingoil-
based and latex house paints
• Thesprayerisoperatingatpeakperformanceatahigh
pressure setting
• Ifthepressureindicatorgoestosolidyellowwhenthe
pressure is set so that it starts at solid green, it indicates one of
thefollowing:
a. Tip Wear Indicator — when spraying with latex or at high
pressure the solid yellow appears. This means the tip is
worn and needs to be replaced.
b.  — when a tip that is too large for the sprayer
is put in the gun, the pressure indicator will turn from solid
green to solid yellow.
c. — if a solid yellow pressure indicator
appears when using a new tip and the pressure is set at
maximum, service may be required (worn packings, worn
piston, stuck valve, etc...).
Service Indicator
The Service indicator is on when the motor is commanded to run.
This indicator is used by service centers to troubleshoot motor
problems.
 
1. Minimum pressure setting
2. Blackzone–nopressuregeneration
3. Bluezone–pulsatingpressureforcleaning
1
2
3
4.4 Connection to the mains network
Attention
The unit must be connected to an appropriately-
grounded safety outlet.
Before connecting the unit to the mains supply, ensure that the line
voltagematchesthatspeciedontheunit’sratingplate.
The connection must be equipped with a residual current protective
device with INF ≤ 30 mA.