8 ProSpray3.29•3.31
GB
Description of unit Starting operation
3.5 Technical data
ProSpray 3.29
110-120Volt,50/60Hz
Max. current consumption: 13 A 15 A
Power cord: 3 x 1.5 mm
2
– 6 m or 4.6m
Acceptance capacity: 1725 Watt 1840 Watt
Max. operating pressure: 221 bar (22.1 MPa)
3,0 l/min 3,8 l/min
Max tip size: 0.029 inch – 0.032 inch –
0.73 mm 0.81 mm
Max. temperature of the
coating material: 43°C
Max viscosity: 25.000 mPa·s
Weight: 43.5 kg
Special high-pressure hose: DN 6 mm, 15 m, connection
thread M 16 x 1.5
590 x 529 x 726 mm
Max sound pressure level: 80 dB (A) *
* Placeofmeasuring:1mindistancefromtheunitand1.6
m above the oor, 12 MPa (120 bar) operating pressure,
reverberant oor.
3.6 Transportation
Pushing or pulling the unit
Pull out the handle (Fig. 2, Item 1) until it will come no further. Insert
the handle – push the buttons (2) on the spars, and then push in the
handle.
2
1
2
3.7 Transportation in vehicle
Secure the unit with a suitable fastening.
4. Starting operation
oil
1. Screw the high-pressure hose (2) to the coating material
outlet (Fig. 3, Item 1).
2. Screw the spray gun (3) with the selected tip onto the high-
pressure hose.
3. Tighten the union nuts at the high-pressure hoses rmly so
that coating material does not leak.
3
2
1
4. Remove the oil cup cap with a straight-slot screwdriver.
5. Fill the oil cup with EasyGlide (Fig. 4) until the oil gauge (4) is
showing that it is full.
Attention
packings.
6. Replace oil cup cap.
7. Press oil button 2-5 times to prime the oiler. Press once for
every eight hours of usage to lubricate the uid section.