28
Installation
Transport the shipping container to the installation site.
Unpack the dust collection system and check for
damage. Contact the carrier if damage is found. Open
the installation kit (refer to Optional Accessories in
the parts listing for installation kits). Install the cover
and debris collection drawer if removed. Slip a hose
clamp over the 3-inch vacuum hose. Slip the hose on
the inlet duct. Move the clamp over the duct to secure
the hose.
Repeat the procedure to connect the hose to the outlet
duct on the grinding machine.
Electrical Connection
Refer to the Dust Collection System Wiring Diagram
for wiring information. Connection to electrical power
should be made by a qualified electrician. Observe local
electrical codes when connecting the machine.
Operation
The dust collection system motor is started by setting
the toggle switch on the motor to the ON position. Set
the switch to OFF to shut down the dust collection
system.
Maintenance
WARNING:
· MAKE SURE YOU DISCONNECT THE ELECTRI-
CAL POWER TO THE DUST COLLECTION SYS-
TEM BEFORE PERFORMING MAINTENANCE.
FAILURE TO DO SO MAY RESULT IN INJURY
TO THE OPERATOR AND/OR MAINTENANCE
PERSONNEL.
· DO NOT OPERATE THE DUST COLLECTION
SYSTEM WITH THE COVER REMOVED. INJURY
TO FINGERS AND HANDS FROM THE FAN
BLADES, AND INGESTION OF LOOSE FITTING
CLOTHING INTO THE AIR INLET WITH
RESULTANT INJURY IS ALSO POSSIBLE.
Cleaning
Periodically dispose of accumulated chips and debris
from the chip drawer. Use a brush to loosen debris from
internal surfaces. Use a vacuum cleaner to clean up
the loosened debris.
Filter
Check for accumulation of debris. Replace the filter at
intervals that you determine are appropriate for your
shop environment and machine utilization.
Drawer Seal
Check the drawer seal periodically and replace if
damaged or missing. Keep the seal in good condition
to help maintain collection system efficiency.
Dust Collection System (Optional)
Outlet filter at rear
removes fine debris
from outlet air stream
ON/OFF switch on
motor at rear of dust
collection system
Removable cover –
remove for interior
cleaning/access to
impeller
Second Inlet
Duct on this side
Inlet Duct – Connect
3 inch hose - secure
with clamp
Chip Drawer -
Pull to Open
Figure 1: Dust Collector Assembled View