Yamaha MU15 Welding System User Manual


 
85
Effect Parameter List
Parameters marked with a in the “Control” column can be controlled from an AC1
(assignable controller 1) and AC2. However, this is valid only for a Variation effect (when
selected for Insertion).
The “Tbl ”column refers to the Effect Data Assigh Table (page 90).
Dry/Wet is valid only for a Variation effect (when selected for Insertion).
Abbreviations used in the effect block diagrams.
LPF=Low Pass Filter
HPF=High Pass Filter
LSF=Low Shelving Filter
HSF=High Shelving Filter
PDF=Peak Dip Filter
ER=Early Reflection
1 Reverb Time 0.3~30.0s 0-69 table#4
2 Diffusion 0~10 0-10
3 Initial Delay 0~63 0-63 table#5
4 HPF Cutoff Thru~8.0kHz 0-52 table#3
5 LPF Cutoff 1.0k~Thru 34-60 table#3
6
7
8
9
10 Dry/Wet D63>W ~ D=W ~ D<W63 1-127
11 Rev Delay 0~63 0-63 table#5
12 Density 0~3 0-3
13 Er/ Rev Balance E63> R~ E=R ~ E<R63 1-127
14
15 Feedback Level -63~+63 1-127
16
No. * Parameter Range Value Tbl
Control
Hall1,2, Room1,2,3, Stage1,2, Plate
1 Reverb Time 0.3~30.0s 0-69 table#4
2 Diffusion 0~10 0-10
3 Initial Delay 0~63 0-63 table#5
4 HPF Cutoff Thru~8.0kHz 0-52 table#3
5 LPF Cutoff 1.0k~Thru 34-60 table#3
6 Width 0.5~10.2m 0-37 table#8
7 Height 0.5~20.2m 0-73 table#8
8 Depth 0.5~30.2m 0-104 table#8
9 Wall Vary 0~30 0-30
10
11 Rev Delay 0~63 0-63 table#5
12 Density 0~3 0-3
13 Er/ Rev Balance E63> R~ E=R ~ E<R63 1-127
14
15 Feedback Level -63~+63 1-127
16
No. * Parameter Range Value Tbl
Control
W-Room, Tunnel, Basement
L
R
L
R
REV
+
+
+
DELAY/ER
HPF LPF
L
R
L
R
REV
+
+
dry (L)
dry (R)
+
DELAY/ER
HPF LPF
1 Lch Delay 0.1~715.0ms 1-7150
2 Rch Delay 0.1~715.0ms 1-7150
3 Cch Delay 0.1~715.0ms 1-7150
4 Feedback Delay 0.1~715.0ms 1-7150
5 Feedback Level -63~+63 1-127
6 Cch Level 0~127 0-127
7 High Damp 0.1~1.0 1-10
8
9
10 Dry/Wet D63>W ~ D=W ~ D<W63 1-127
11
12
13 EQ Low Frequency 50Hz~2.0kHz 8-40 table#3
14 EQ Low Gain -12~+12dB 52-76
15 EQ High Frequency 500Hz~16.0kHz 28-58 table#3
16 EQ High Gain -12~+12dB 52-76
No. * Parameter Range Value Tbl
Control
DelayLCR
L
R
L
R
LSF HSF
dry (L)
L
R
C
dry (R)
LSF HSF
+
DELAY
LPF
1 Lch Delay 0.1~715.0ms 1-7150
2 Rch Delay 0.1~715.0ms 1-7150
3 Feedback Delay 1 0.1~715.0ms 1-7150
4 Feedback Delay 2 0.1~715.0ms 1-7150
5 Feedback Level -63~+63 1-127
6 High Damp 0.1~1.0 1-10
7
8
9
10 Dry/Wet D63>W ~ D=W ~ D<W63 1-127
11
12
13 EQ Low Frequency 50Hz~2.0kHz 8-40 table#3
14 EQ Low Gain -12~+12dB 52-76
15 EQ High Frequency 500Hz~16.0kHz 28-58 table#3
16 EQ High Gain -12~+12dB 52-76
No. * Parameter Range Value Tbl
Control
DelayLR
L
R
L
R
LSF HSF
dry (L)
L
R
dry (R)
LSF HSF
+
DELAY
LPF
LPF
Reverb Block
Variation Block