32 Instruction manual TWI 35-130 G/TWI 45-190 G
3.11.2 Adjust the CO
2
-value
For preparation remove the cover plate (2) from the electricity part by loosening
the two screws (1).
1. Remove the cap (3) from the CO
2
setting screw (4).
2. Insert a long screwdriver into the setting hole (5) along the air supply pipe.
3. Correct the CO2-value dependent on the deviation by turning the CO
2
setting screw (4).
- CO
2
setting screw clockwise: CO
2
-value decreases
- CO
2
setting screw counterclockwise: CO
2
-value increases
4. Put back the cap (3) on the CO2 setting screw (4).
5. Remount the cover plate (1).
Remark
Before starting up, take the time for completing the delivered warranty
card. In this way you enable us to guarantee the quality of our systems and to
optimise our warranty procedure.
Return this card as soon as possible. Your customer will then receive a
warranty certi cate with our terms of warranty.
3