7. Once the bottom of the suction tube touches the base of the drum, securely fasten the bung onto the
drum. Now tighten the bung onto the suction tube
8. When using the pump for the first time or after an extended period of time or using the pump to lift Fuels/
Low viscosity Media; make sure to Prime before use. To Prime, POUR 30 ML OF MEDIA BEING
PUMPED/ OIL INTO THE PUMP OUTLET. RAPIDLY ROTATE THE PUMP HANDLE TILL PUMP
STARTS DISPENSING. In everyday use, it may take about 10 rotations of the crank for pump to start
dispensing
9. When not in use, you may chose to lock the pump using a padlock. Crank has a link under it which fits
onto the lock latch on the pump body.
10. For Pump Models supplied with hose assembly, you may use the nozzle holder, located adjacent the
crank & crank shaft connection to store the hose when not in use
USING FUEL FILTER WITH PUMP
This pump is designed for use with a Fuel Filter. This can be done by connecting the pump outlet directly to the
Fuel Filter, using a straight steel extension. Note: Pump outlet is threaded ¾” BSPT (F)
CAUTION
1. Use of this equipment to pump fluids other than approved will void the manufacturing warranty
2. Never open the pump Assembly.
3. This pump is NOT U/L approved. If local laws do not allow for Fuels to be pumped using Non U/L approved pumps; you
must not use this pump for dispensing fuel.
4. This is a Rapid Action Pump & dispenses very large amount of media with each rotation. Be careful not to over dispense. It is
also recommended to lock the crank when not in use, as even slight un-intentional rotation will cause a lot of discharge
5. Never operate the pump near fire or source of spark. Some Media may be Explosive & Hazardous
6. Pump should only be used in well-ventilated areas. Never fill containers in confined areas, e.g. inside a vehicle. Do not operate
pump in areas where vapors can accumulate
7. Precautions are necessary to minimize the build-up of static charge, which could cause sparking
8. Always use genuine anti-static hose when pumping petrol and other flammable liquids.
9. Fuel storage tanks and drums should be metal and grounded to earth. Ensure the floor or ground where fuel is stored or
dispensed is and remains electrically conducive
10. Wear anti-static or conductive footwear and avoid wearing silk and/or synthetic clothing, unless treated with anti-static solution
11. Avoid prolonged skin contact with petroleum products. Use of protective goggles, gloves and aprons is recommended in case of
accidental splashing or spillage. Change clothing and wash skin contact areas promptly with soap and water
12. When carrying out maintenance of this pump, for your own protection, thoroughly drain the pump and hose before disassembly.
Clean flammable liquids from components as they are removed from the pump. Follow precautions when handling flammable
liquids
S1240, Rev-C