REPLACEMENT PARTS
Available Parts: Please refer to the Parts drawing when ordering parts. Not all components of this kit are replace-
ment items, but are illustrated as a convenient reference of location and position in the assembly sequence. When
ordering parts, give Model number, serial number and description below. Call or write for current pricing:
Atd Tools Inc. 160 Enterprise Drive, Wentzville, MO 63385 Tel:(636)327-9050 Fax:(636)327-9046
Symptom Possible Causes Corrective Action
Ram will not press load
• Release valve not tightly closed
• Overload condition
• Faulty/ Loose couplers
• Oil lever in pump is low
• Ensure release valve tightly closed
Remedy overload condition
• Replace/ Tighten couplers
• Fill and bleed system
Ram bleeds off after press operation Release valve not tightly closed
• Oil lever in pump is low
Ram or Bottle Jack malfunction
Ensure release valve tightly closed
• Fill and bleed system
Contact Atd Tools Tech. Service
Ram will not retract after unloading • Reservoir overlled
• Linkage binding
• Drain uid to proper level
• Clean and lubricate moving parts
Poor lift performance • Fluid level low
Air trapped in system
• Ensure proper uid level
With ram fully retracted, remove oil
ller plug/screw to let pressurized
air escape, then reinstall oil ller
plug/screw
Ram will not extend to full extension • Fluid level low Ensure proper uid level