Examples of the settings are as follows.
(Example 1) Parameter ID = 67 16
Parameter ID = 68 1
XY2-100 specification compatible
Note: The above N bit data is not used. It does not matter if it is either 1 or 0.
(Example 2) Parameter ID = 67 16
Parameter ID = 68 3
(Example 3) Parameter ID = 67 18
Parameter ID = 68 2
(Example 4) Parameter ID = 67 20
Parameter ID = 68 0
Bit
1234567891011121314151617181920
DATA (AXIS 1)
ND15D14D13D12D11D10D9D8D7D6D5D4D3D2D1D0 N N N
DATA (AXIS 2)
ND15D14D13D12D11D10D9D8D7D6D5D4D3D2D1D0 N N N
16bit
3bit
(
パラメータ
ID = 67) (
パラメータ
ID = 68)
Bit
1234567891011121314151617181920
DATA (AXIS 1)
D17 D16 D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 N N
DATA (AXIS 2)
D17 D16 D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 N N
18bit
2bit
(
パラメータ
ID = 67) (
パラメータ
ID = 68)
Bit
1234567891011121314151617181920
DATA (AXIS 1)
D19 D18 D17 D16 D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
DATA (AXIS 2)
D19 D18 D17 D16 D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
20bit
0bit
(
パラメータ
ID = 67) (
パラメータ
ID = 68)
Bit
1234567891011121314151617181920
DATA (AXIS 1)
N N ND15D14D13D12D11D10D9D8D7D6D5D4D3D2D1D0 N
DATA (AXIS 2)
N N ND15D14D13D12D11D10D9D8D7D6D5D4D3D2D1D0 N
16bit
1bit
(
パラメータ
ID = 67) (
パラメータ
ID = 68)
(Parameter
(Parameter
(Parameter
(Parameter
(Parameter
(Parameter
(
P
a
r
a
m
ete
r
(Parameter