4–33
Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide
NOTE: Figure 4–5 shows an example of a heterogeneous host configuration. For
supported host operating systems, refer to the
HSZ80 Array Controller ACS
Version 8.3 Release Notes
.
Figure 4–5. Assigning Units through Multiple Host Adapters
To reassign target 1 to the Windows NT server host mode, use the following syntax:
SET THIS HOST_FUNCTION (1,D)
To assign the units to each host using SCSI ID numbers, yet restrict host access by the
other hosts, use the following syntax:
SET D100 THIS_PORT_1_DISABLE_ACCESS_PATH = ALL
SET D100 OTHER_PORT_1_DISABLE_ACCESS_PATH = ALL
SET D100 THIS_PORT_1_ENABLE_ACCESS_PATH = 7
SET D100 OTHER_PORT_1_ENABLE_ACCESS_PATH = 6
HSZ80 controller A
Port 1 Port 2
CXO6488A
HSZ80 controller B
Port 1 Port 2
Device bus
D100 D101 D102 D200 D201
Host bus
Host bus
Windows
NT
Digital
UNIX
SCSI ID 7 SCSI ID 6
SCSI ID 7
SCSI ID 6