INSTALLATION
1. Usethepredrilledmountingholesinthemanifoldbracketasguides.Markanddrillanchorholes.
Mountsecurely.SeeFigures1-4.
2. Shutoffpowertomachine.
3. ConnectoutletportofInsuricesystemtoequipmentserved.AlwaysuseaNSFapprovedpipedope
orTeontapeatallconnections.Useabackupwrenchonallttingswhileconnectingtoavoid
excessive stress on the system components.
Note: If the optional E-Series Filter is used, install a manual shut-off valve leading to the system
for servicing.
4. Connectminimum3/8”waterlinetoinletsideofInsuricesystem.
5 Connecttubingtoushingvalveandruntodrain.
Note: Some municipal plumbing codes and good sanitary practices require an air gap at the drain
termination point.
6. Installthecartridge(s)intotheInsuricesystemhead(s)followingdirectionsonthecartridgelabelor
asshownintheCartridgeChangeillustrations.
7. Turnonwatertolterandcheckforleaks.
8. Flushthecartridgebyrunningwaterthroughatfullforceforveminutes.Thiswillsettheltering
mediaandpurgeairandnes,insuringmaximumlterlife.
9. Afterushing,closetheushingvalve,turnonpowertoequipmentandplugtheLPA(ifso
equipped)intotheelectricaloutlet.Seeillustrations.
CARTRIDGE CHANGE DETERMINATION
Replacecartridgeswhencapacityisreached,orwhenowbecomesinadequate,butatleastannually.
Allcartridgesonmultiplecartridgesystemsshouldbechangedatthesametime.TheEverpure
PressureGaugeorEverguardLowPressureAlarmprovidesaquickandsimplemeansofdetermining
whentheltercartridge(s)shouldbechanged.Installedontheoutletportofthelter,thegauge
orEverguardLPAcanbeusedtomeasurebothdynamic(owing)andstatic(line)pressure.The
cartridge(s)shouldbechangedwhenthepressuregaugeneedleisintheredareawhileequipment
isinoperation,andyettheneedleshowsadequatelinepressurebetweencycles.Observetheneedle
duringthenextequipmentoncycle.Iftheneedleregistersadequatepressure,itcanbeassumedthat
thetemporarylow-pressureconditionwascausedbyabriefpowerfailureorotherincomingpressure
disruption.
FLUSHING
For maximum life, all carbon filter cartridges must be flushed for five minutes at full flow before use. ALL
NEW CARTRIDGES MUST BE FLUSHED AFTER EACH CARTRIDGE CHANGE BEFORE BEING PUT INTO SERVICE!
Ifthecartridgesarenew,havebeenproperlyushedandbothneedleandfollowerregisterinadequatepressure,or
theLPAissounding,youmaybeexperiencinginadequatewaterpressureorsomerestrictionmayexistintheinlet
waterline.Ineithercase,theincomingwaterpressuremustbeimprovedtoreceiveoptimumlterlife.
COMPLETECARTRIDGECHANGEINSTRUCTIONSCANBEFOUNDONTHEFILTERCARTRIDGELABEL.
Not for residential use. For food service applications only.
Figure5–InsuriceSingleSystem
OUTLET
3/8" FNPT
INLET
3/8" FNPT
27.50"
5.60"
Figure6–InsuriceTwinSystem
16.60"
OUTLET
3/4" FNPT
INLET
3/4" MNPT
25.26"
Figure8–InsuriceQuadSystem
24.60"
OUTLET
3/4" FNPT
INLET
3/4" MNPT
29.69"
Figure7–InsuriceTripleSystem
21"
OUTLET
3/4" FNPT
INLET
3/4" MNPT
29.26"
Checkforcompliancewithstateandlocallaws
andregulations.Donotusewithwaterthatis
microbiologicallyunsafeorofunknownqualitywithout
adequatedisinfectionbeforeorafterthesystem.Systems
certiedforcystreductionmaybeusedondisinfected
watersthatmaycontainlterablecysts.