A SERVICE OF

logo

MA250-EU-EN-V3.2-6/11
11
General Specifications
Clamp jaw opening 30mm (1.18") approx.
Display 4,000 count LCD
Continuity check Threshold <150Ω; Test current < 0.5mA
Diode test Test current of 0.3mA typical;
Open circuit voltage [ 1.5VDC typical
Low Battery indication Battery symbol is displayed
Over-range indication ‘OL’ display
Measurement rate 2 readings per second, nominal
Thermocouple sensor Type K thermocouple required
Input Impedance 10MΩ (VDC and VAC)
AC bandwidth 50 to 400Hz (VAC)
AC response Average responding
Operating Temperature 5°C to 40°C (41°F to 104°F)
Storage Temperature -20°C to 60°C (-4°F to 140°F)
Operating Humidity Max 80% up to 31°C (87°F) decreasing linearly to 50% at 40°C
(104°F)
Storage Humidity <80%
Operating Altitude 2000meters (7000ft) maximum.
Battery Two “AAA” 1.5V batteries
Auto power OFF After approx. 30 minutes
Dimensions & Weight 200x66x37mm (7.9x2.6x1.5”); 205g (7.23oz)
Safety For indoor use and in accordance with the requirements for double
insulation to IEC1010-1 (2001): EN61010-1 (2001) Overvoltage
Category III 600V, Pollution Degree 2.
Approvals CE,
Copyright © 2011 Extech Instruments Corporation (a FLIR company)