1. PREFACE
This service manual provides various service information, including the mechanical and electrical parts, etc.
This room air conditioner was manufactured and assembled under a strict quality control system.
The refrigerant is charged at the factory. Be sure to read the safety precautions prior to servicing the unit.
1.1 FEATURES
DESIGNED FOR COOLING ONLY
BUILT-IN ADJUSTABLE THERMOSTAT
WASHABLE ONE-TOUCH FILTER
COMPACT SIZE
1.2 SPECIFICATIONS
—2—
1.2-2 SPECIFICATIONS
MODELS
ITEMS
COOLING CAPACITY (BTU/h)
5,450
POWER SUPPLY (Phase, V, Hz) 1ø, 115V, 60HZ
INPUT (W) 510
OPERATING CURRENT (AMP.) 4.8
REFRIGERANT CONTROL CAPILLARY TUBE
REFRIGERANT CHARGE (R410A) 280g (9.9 oz)
INSIDE FAN TURBO FAN
OUTSIDE FAN PROPELLER FAN WITH SLINGER RING
AIR DISCHARGE 2-WAY (RIGHT AND LEFT)
CHASSIS TOP-DOWN
PROTECTOR
TEMPERATURE CONTROL THERMISTOR
FAN MOTOR
OVERLOAD PROTECTOR FOR COMPRESSOR
,17(51$/3ROTECTOR FOR FAN MOTOR
4 POLES,21W