A SERVICE OF

logo

ENWW
Configure device menu 149
1
6
OPTIMIZE TRANSFER UP 1
TRANSFER UP 2
TRANSFER DOWN 1
TRANSFER DOWN 2
HIGH COVERAGE 1
HIGH COVERAGE 2
HIGH COVERAGE 3
LEADING EDGE UP
LEADING EDGE DOWN
RESTORE OPTIMIZE
Use this item to optimize a number of engine parameters for all
jobs rather than by media type. Each item can be set to OFF or
ON. The default value of each item is OFF. The RESTORE
OPTIMIZE option resets all options to the factory default
position (OFF). For more information about optimize values,
see chapter 8 of the User Reference Guide on the CD-ROM.
QUICK CALIBRATE
NOW
No value to select. Use this item to perform only DMax and DHalf color-tone
adjustments.
FULL CALIBRATE NOW No value to select. Use this item to perform DMax, DHalf, and color-plane
registration (CPR) adjustments.
PROCESS CLEANING
PAGE
No value to select. This item appears only after a cleaning page is generated.
To uch C
ONTINUE to process the cleaning page. The progress
bar shows how long until the process is complete.
Item Values Explanation