8
4. ■ If using the rear electrical knockout, drill a 1¹⁄₄" (3.0 cm)
dia. hole through the wall at the location shown.
■ If using the top electrical knockout, drill a 1¹⁄₄" (3.0 cm)
dia. hole through the hood support at the location shown.
5. Remove the filters. Use two hands to remove filter. Push tab
back to release the locking pin, pull down and forward. Set
filter aside. Repeat with other filter(s).
6. Remove the wiring box cover located behind the right hand
filter.
7. Install UL- or CSA-listed strain relief in hood liner so that
screws can be tightened.
Make Electrical Connection
1. Disconnect power.
2. Run power supply cable to the hood electrical hole according
the National Electrical Code or CSA Standards and local
codes and ordinances. There must be enough power supply
cable from the fused disconnect (or circuit breaker) box to
make the connection in the hood’s electrical wiring box.
3. Remove the four mounting screws from the parts bag. It is
recommended they be placed by the holes in the hood liner
support for quick access.
4. While feeding the wiring through the strain relief, lift the hood
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.