logo

KYOCERA Solar, Inc. 800-223-9580 800-523-2329 fax www.kyocerasolar.com
OUR VALUED PARTNER040513
KD 300-80 P SERIES
ELECTRICAL SPECIFICATIONS
MODULE CHARACTERISTICS
Dimensions: 65.43in/51.97in/1.8in
length/width/height
(1662mm/1320mm/46mm)
Weight: 60.6lbs (27.5kg)
PACKAGING SPECIFICATIONS
Modules per pallet: 20
Pallets per 53’ container: 22
Pallet box dimensions: 66in/53in/47in
length/width/height
(1675mm/1330mm/1190mm)
Pallet box weight: 1323 lbs (600kg)
Expanded View of Grounding Holes Frame Cross Section Diagrams
Short Side
Long Side
11.06in
281mm
1.8in
46mm
.47in
12mm
1.18in
30mm
1.8in
46mm
1.18in
30mm
.41in
10.3mm
KD 315-80
Weight: 60.6lbs (28.0kg)
65.43in
1662mm
11.06in
281mm
21.65in
550mm
51.97in
1320mm
1.8in
46mm
0.87in
22mm
21.65in
550mm
11.06in
281mm
STABILIZER BAR
STABILIZER BAR
(
IP65
)
5.24in
133mm
5.36in
136mm
50.8in
1290mm
40.9in
1040mm
MOUNTING HOLES DRAINAGE HOLES GROUND SYMBOL
.35in
(
9mm
)
.35in
(
9mm
)
WARNING: Read the instruction
manual in its entirety prior to
handling, installing & operat-
ing Kyocera Solar modules.
Standard Test Conditions (STC)
STC = 1000 W/M
2
irradiance, 25
o
C module temperature, AM 1.5 spectrum*
KD315GX-LPB KD320GX-LPB
P
mp
315 320 W
V
mp
39.8 40.1 V
I
mp
7.92 7.99 A
V
oc
49.2 49.5 V
I
sc
8.50 8.60 A
P
tolerance
+5/-3 +5/-3 %
Nominal Operating Cell Temperature Conditions (NOCT)
NOCT = 800 W/M
2
irradiance, 20
o
C ambient temperature, AM 1.5 spectrum*
T
NOCT
45 45
o
C
P
max
226 230 W
V
mp
35.8 36.1 V
I
mp
6.34 6.40 A
V
oc
45.0 45.3 V
I
sc
6.88 6.96 A
PTC
276.4 280.9 W
Temperature Coefficients
P
max
-0.46 -0.45 %/
o
C
V
mp
-0.52 -0.51 %/
o
C
I
mp
0.0064 0.0065 %/
o
C
V
oc
-0.36 -0.36 %/
o
C
I
sc
0.061 0.060 %/
o
C
Operating
Temp
-40 to +90 -40 to +90 %/
o
C
System Design
Series Fuse Rating
15 A
Maximum DC System Voltage (UL)
600 V
Hailstone Impact 1in (25mm) @ 51mph (23m/s)
*
Subject to simulator measurement uncertainty of +/- 3%.
KYOCERA reserves the right to modify these specifications without notice.
NEC 2008 COMPLIANT
UL 1703 LISTED