20 21
LV150/150A
Main specifications
Main body Baseless type (spacer insertable between arm and stand); Max. sample height 47mm (when configured with 3x2 stage/6x4 stage),
82mm with column riser, 116.5mm with Suruga Seiki B23-60CR; 12V-50W brightness control transformer built in
Focusing section Coaxial coarse/fine focus knob, left: coarse/fine, right: fine; Stroke 40mm, coarse 14.0mm/rotation (torque adjustable, with
refocusing mechanism), fine focusing 0.1mm/rotation (1mm/increments)
Nosepiece C-N6 Nosepiece (brightfield, sextuple), L-NBD5 Nosepiece (bright/darkfield quintuple, with flare prevention), L-NU5 Nosepiece
(universal quintuple, with flare prevention), LV-NU5A Nosepiece (for LV150A, high-durability motorized universal quintuple, with
flare prevention)
Episcopic illuminator 12V-50W high-intensity halogen lamp (ESD-applied); Field (centerable) and aperture diaphragms synchronized with B/D
LV-U EPI changeover; ø25mm filter (NCB11, ND16, ND4) insertable; Polarizer/analyzer mountable
Episcopic illuminator 12V-50W high-intensity halogen lamp (ESD-applied); 120W high-intensity mercury-fiber illuminator (with brightness
LV-U EPI2 control, no centering necessary) mountable; Centerable field and aperture diaphragms synchronized with B/D changeover;
f25mm filter (NCB11, ND16, ND4) insertable; Polarizer/analyzer/l plate insertable, excitation balancer insertable
Eyepiece tube LV-TI3 Trinocular (erect image, F.O.V. 22/25), LV-TT2 Tilting Trinocular (erect image, F.O.V. 22/25), Y-TF Trinocular (inverted
image, F.O.V 22/25), Y-TB Binocular (inverted image, F.O.V 22), C-TE Tilting Binocular (inverted image, F.O.V 22)
Stage LV-S32 3x2 Stage (stroke: 75x50 mm including glass plate), ESD-applied (excluding glass plate)
LV-S64 6x4 Stage (stroke: 150x100 mm including glass plate), ESD-applied (excluding glass plate)
LV-S6 6x6 Stage (stroke: 150x150 mm; only for episcopic illumination)
Eyepiece CFI eyepiece series
Objective lens CFI60 series
Electrostatic decay time 1000-10V, within 0.2 sec.
Power consumption 1.2A/75W
Weight Approx. 8.6kg
LV100D
Main body Baseless type (spacer insertable between arm and stand); Max. sample height 29mm, 64mm with column riser; 12V-50W
brightness control transformer built in
Focusing section Coaxial coarse/fine focus knob, left: coarse/fine, right: fine; Stroke 30mm, coarse 14.0mm/rotation (torque adjustable, with
refocusing mechanism), fine focusing 0.1mm/rotation (1mm/increments)
Nosepiece C-N6 Nosepiece (brightfield, sextuple), L-NBD5 Nosepiece (bright/darkfield quintuple, with flare prevention), L-NU5 Nosepiece
(universal quintuple, with flare prevention)
Episcopic illuminator 12V-50W high-intensity halogen lamp (ESD-applied); Field (centerable) and aperture diaphragms synchronized with B/D
LV-U EPI changeover; f25mm filter (NCB11, ND16, ND4) insertable; Polarizer/analyzer insertable
Episcopic illuminator 12V-50W high-intensity halogen lamp (ESD-applied); 120W high-intensity mercury-fiber illuminator (with brightness control,
LV-U EPI2 no centering necessary) mountable; Centerable field and aperture diaphragms synchronized with B/D changeover; f25mm filter
(NCB11, ND16, ND4) insertable; Polarizer/analyzer/l plate insertable, excitation balancer insertable
Diascopic illuminator 12V-50W high-intensity halogen lamp; Field (centerable) and aperture diaphragms synchronized with B/D changeover; Filters
(ND8, NCB11) insertable
Eyepiece tube LV-TI3 Trinocular (erect image, F.O.V. 22/25), LV-TT2 Tilting Trinocular (erect image, F.O.V. 22/25), Y-TF Trinocular (inverted
image, F.O.V 22/25), Y-TB Binocular (inverted image, F.O.V 22), C-TE Tilting Binocular (inverted image, F.O.V 22)
Stage LV-S32 3x2 Stage (stroke: 75x50 mm including glass plate)
LV-S64 6x4 Stage (stroke: 150x100 mm including glass plate)
Eyepiece CFI eyepiece series
Objective lens CFI60 series
Electrostatic decay time 1000-10V, within 0.2 sec.
Power consumption 1.2A/75W
Weight Approx. 9.4kg
Polarizers/analyzers/plate