![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/c/e1/ce173f3d-88c0-4099-b78b-f5e03872ce36/ce173f3d-88c0-4099-b78b-f5e03872ce36-bg11.png)
15
Table 8. Alarm Configuration Options (2 of 2)
Option Comments/DescriptionFactory 2Factory 1
AlrmRelay:
Enab Enab
Specifies whether to activate the
(Alarm Relay)
Disab Disab
alarm relay on an alarm condition.
Table 9. General Management Configuration Options (1 of 2)
Option Factory 1 Factory 2 Comments/Description
Enab Enab
Specifies whether the DSU/CSU
SNMP Mgt:
Disab Disab
responds to SNMP session
requests.
Enab Enab
Specifies whether the DSU/CSU
validates the IP address of an
NMS Valid:
Disab Disab
SNMP manager attempting
access.
1 1
The number of SNMP managers
Num Sec Mgrs:
2–10 2–10
allowed to access the DSU/CSU.
Edit Edit
Allows you to define or clear the
allowable IP address of an SNMP
NMS
n
IP Adr:
Clear Clear
allowable IP address of an SNMP
manager.
Read Read
The type of access allowed for an
SNMP manager using community
NMS
n
Access:
R/W R/W
SNMP manager using community
name 1.
Edit Edit
The SNMP system name for this
System Name:
Clear Clear
device.
Edit Edit
The SNMP system location for this
System Location:
Clear Clear
device.
Edit Edit
The SNMP system contact name
System Contact:
Clear Clear
for this device.
Edit Edit
A community name that is allowed
access to this device Defaults to
CommunityName1:
Clear Clear
access to this device. Defaults to
public
.
Read Read
The type of access allowed for
Access 1:
R/W R/W
community name 1.
Edit Edit
A community name that is allowed
CommunityName2:
Clear Clear
access to this device.
Read Read
The type of access allowed for
Access 2:
R/W R/W
community name 2.