A SERVICE OF

logo

12 C2635M (1/07)
MOVING THE MAIN CAPTURE CARD TO SLOT 3
In the DX8108 and DX8116 base DVRs, the main Capture Card is installed in slot 2. To install the DX8100-ISCI SCSI card, the main Capture Card
must be removed from slot 2 and re-installed into slot 3. This step is necessary because the DX8100-ISCI SCSI card must be physically installed
in slot 2.
For information about preparing the DX8100 for the DX8100-ISCI SCSI card installation, refer to Preparing the DX8100 for SCSI Card Installation
on page 10.
Move the main Capture Card from slot 2 to slot 3:
1. To ready the main Capture Card for removal, do the following:
a. Remove the rear cross-brace.
b. Remove the slot cover for slot 3 and retain the screw.
c. Remove the bracket screw that secures the main Capture Card in slot 2.
d. Disconnect the 32-pin ribbon cable.
e. Disconnect the 5-wire TV/Audio cable and lay the cable over the DX8100 I/O Card.
f. Disconnect the 7-wire TV/Audio cable.
g. Disconnect the 2-wire audio cable.
Figure 7. Readying Main Capture Card for Removal
2. To move the main Capture Card, do the following:
a. Remove the Capture Card from slot 2 and firmly seat the Capture Card in the PCI connector for slot 3.
b. Secure the Capture Card bracket with the screw.
c. Reconnect the 5-wire TV/Audio cable.
d. Reconnect the 7-wire TV/Audio cable.
e. Reconnect the 2-wire audio cable.