A SERVICE OF

logo

Error Code Table
Error
number
Explanation Valid for
PEMG99
Addresses
in HCS
Remarks
0 No error X X
1 FBX 3V3 protection X X
2 No Horizontal Flyback protection X X GDE reported critical error
HFB error
3 X-Ray protection
Significance changed to:
GDE critical error – Vertical
Output Failure
X Must have been supported by
GDE. But it is not so.
GDE reported critical error
4 +5V protection active (detected via
MSP34xx & tuner)
X X
5
HOP POR not successful
X X GDE reported critical error –
HOP Initialization Failure
6
General I
2
C error main I
2
C bus
X X
7 Mains Dip error
Significance changed to:
GDE critical error – DAC
Initialization failure
X
X
Cannot be supported in HCS
since the hardware supports.
GDE reported critical error
8
3D Comb filter I
2
C communication
error
X X
9 Bocma IC TDA888xx 8V failure
(SUP bit)
Significance changed to:
HCS-GDE communication failure
X
GDE did not communicate
with Initialization complete
message.
10
NVM IC STM24xxx I
2
C
communication failure
X X
11 New NVM IC error (NVM_
IDENTIFICATION_ERROR)
X X
12 Main uP (Painter) Internal RAM test
failure
X X
13
Main tuner I
2
C failure UV13xx
X X
14
Sound IC MSP34xx I
2
C failure
X X
15 SRAM IC uPD431000A-B test
failure
X X
16
PIP/DW Tuner (ETA50) I
2
C failure
X X
17
PIP IC M65669SP I
2
C failure or
Double window IC SAB9081 I
2
C
failure
X X