Regency E21 Gas Fireplace Insert
Before leaving this unit with the customer, the
installer must ensure that the appliance is fi ring
correctly. This includes:
Clocking the appliance to ensure the
correct fi ring rate (rate noted on label) at
If required, adjusting the primary air to ensure
that the fl ame does not carbon. First allow
the unit to burn for 15 min. to stabilize.
Turn gas control knob counter clockwise to
Use the rocker switch to operate main
Rotate the variable fl ame control to adjust
the fl ame height higher or lower.
Close the bottom louver assembly.
Use the rocker switch to turn off the main
Open the bottom louver assembly.
Push in the gas control knob slightly and
turn clockwise to "OFF". Do not force.
4) Disconnect all electric power and gas
to the appliance if service is to be
The fi rst fi re in your stove is part of the paint
curing process. To ensure that the paint is
properly cured, it is recommended that you
burn your fi replace for at least four (4) hours the
fi rst time you use it with the fan on. When fi rst
operated, the unit will release an odour caused
by the curing of the paint, the burning off of
any oils remaining from manufacturing. Smoke
detectors in the house may go off at this time.
Open a few windows to ventilate the room for
The glass panel may require cleaning after the
DO NOT ATTEMPT TO CLEAN THE
Do not use abrasive cleaners on
Note: When the glass is cold and the
appliance is lit, it may cause
condensation and fog the glass.
This condensation is normal and will
disappear in a few minutes as the
DO NOT BURN THE APPLIANCE
WITHOUT THE GLASS FRONT IN
Before operating this appliance, proceed through
the following check list.
Read and understand these Instructions
operating this appliance.
Check to see that all wiring is correct and
enclosed to prevent possible shock.
IMPORTANT: Gas cock knob cannot be
turned from "PILOT" to "OFF" unless it is
Open the bottom louver assembly
If the control knob is in the "OFF" position
Push in gas control knob slightly and turn
clockwise to "OFF". Knob cannot be turned
from "PILOT" to "OFF" unless knob is
pushed in slightly. Do not force.
Wait fi ve minutes to allow gas, that may
have accumulated in the main burner
compartment, to escape. If you do smell
gas, follow the instructions on the front of
this manual. If you don't smell gas continue
Turn the gas control counter clockwise to
Push in control knob all the way and hold
in. Continually push and release the black
button on spark igniter until pilot lights.
Continue to hold the control knob in for
approximately one minute, then release
the gas control knob. The pilot fl ame should
continue to burn. If the pilot does not remain
lit, repeat operation allowing a longer period
before releasing gas control knob.
Verify log placement. If the pilot cannot be
seen when lighting the unit - the logs or the
embers have been incorrectly positioned.
The unit should never be turned off and on
again without a minimum of a 60 second
When lighting the appliance, the inside of
the glass may fog up, this will burn off after
a few minutes of operation.
Check to ensure there are no gas
Make sure the glass door is in place.
operate the appliance with the door glass
Verify that all venting and the cap is
Gas In
Shut Of
f
Hi-Low
Pilot Adjust
Gas Out
TPTH
TP
TH
Any alteration to the product that causes
sooting or carboning that results in
damage to the unit is not the responsibility
of the manufacturer and will not be