![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/8/da/8da1c921-4657-4aba-b664-7bc36bad7fbe/8da1c921-4657-4aba-b664-7bc36bad7fbe-bg9.png)
14450 Heat Gun
7
Maintenance
1. The brushes in your heat gun should be checked for wear at ap-
proximately 400 hours of operation. Replace in sets when they
reach a length of ˘” or less. Brush springs should be replaced at
the same time.
Remove brushes by unscrewing retainer caps on sides of motor
housing. If old brushes are reinstalled, replace as removed to
ensure same commutator match.
2. Bearings are factory lubricated and sealed for the life of the bearing
and no further lubrication is required.
3. If the heat gun is used under extremely dusty conditions, dust
inside the housing can be removed without disassembly with a
blast of compressed dry air through openings in the housing.
4. If housing exterior requires cleaning, any household liquid deter-
gent may be used. Be careful not to allow liquid of any kind to
reach the gun’s operating parts. Avoid using MEK or strong alka-
line solutions.
5. Inspect the cord and plug occasionally to ensure protective insula-
tion is not damaged.
6. In the event of heating element burn-out, the complete “Quick
Change” assembly can be ordered with installation instructions.
ACCESSORIES
Safety Stand
This stand is a sturdy, circular safety stand of LEXAN 940 that can be
easily adjusted to any angle in horizontal or vertical position. Easily
attached and removed.