Command Descriptions
2–336
TDS Family Oscilloscope Programmer Manual
TRIGger:MAIn:VIDeo:NTSc { MONo | COLOr }
TRIGger:MAIn:VIDeo:NTSc?
<Space>
?
TRIGger :
:
MONo
COLOr
VIDeo
MAIn
NTSc
:
MONo specifies mode for noncolor signals.
COLOr specifies mode for color field triggering and enables numeric triggering.
TRIGGER:MAIN:VIDEO:NTSC MONO
specifies numeric fields are invalid.
TRIGger:MAIn:VIDeo:PAL
TDS 510A, 500C, 600B, & 700C Option 05 Only
Sets or queries the PAL video trigger mode selection. This is equivalent to
toggling 625/PAL in the video main-menu pop-up, Mode in the main menu, and
a side menu item (PAL, Mono, or SECAM).
Trigger
TRIGger:MAIn:VIDeo:PAL { MONo | COLOr | SECAm }
TRIGger:MAIn:VIDeo:PAL?
<Space>
?
TRIGger :
:
COLOr
VIDeo
MAIn
PAL
:
MONo
SECAm
MONo specifies mode for non-color signals.
COLOr specifies mode for color field triggering and enables numeric triggering.
Syntax
Arguments
Examples
Group
Syntax
Arguments