Model MRC44 Page: 51
© 2002 Xantech Corporation
PROBLEM PROBABLE CAUSE AND SOLUTION
When Transferring the project to a MRC44, the transfer
stops with a "Transfer aborted-Receiver Stopped
Responding" or a "Communications Error---" message.
The following items may have interfered with the
transfer of data. Check each one in the order listed,
then redo the transfer.
a) A corrupted or incorrectly learned IR code may
exist in the data. Refer to item 1, previous, for
correction.
b) Check the COM PORT interface cable for
continuity on each of its 3 leads. Replace if
necessary.
c) Your computer may have run out of system
resources (memory). Quit other open applications
and restart Windows.
After transferring commands to the MRC44, it works fine
... except at certain times the MRC44 refuses to output
any commands at all.
IR noise may be on the IR bus line coming from an IR
receiver in another room or rooms, preventing a clean
IR signal from arriving at the controlled component.
a) Temporarily disconnect each MRC44 Keypad one
at a time, until you find the one causing the
interference.
b) Look for sources of IR interference near the IR
receiver(s) [such as CFL lamps, TVs, Neon
lighting, etc.]. Move or shade the IR receiver(s) or
take other steps as necessary.
Windows and Microsoft are registered trademarks of Microsoft Corporation.
IBM is a registered trademark of International Business Machines Corporation.