3Com 3016 (3C13616) Saw User Manual


 
Router 3013 and Router 3015 13
AUX Port
Table 12 lists attributes of the AUX port.
Ethernet Port
Table 13 lists attributes of the Ethernet port.
Synchronous/Asynchronous Serial Port
Table 14 lists attributes of the serial port.
Table 12 Attributes of the AUX Port
Attribute Description
Connector RJ-45
Port standard Asynchronous EIA/TIA-232
Baud rate 300 bps to 115.2 kbps
Services Modem dial-up
Backup
Protocols PPP (Point to Point Protocol)
SLIP (Serial Line Internet Protocol)
MP (Multilink PPP)
Table 13 Attributes of the Fast Ethernet Port
Attribute Description
Connector RJ-45
Frame format Ethernet_II
Ethernet_SNAP
IEEE 802.2
IEEE 802.3
Operating mode 10/100 Mbps autosensing
Full duplex/half duplex
Network protocol IP (Internet Protocol)
Novell IPX (Internet Packet Exchange)
Table 14 Attributes of the Serial Port
Attribute
Description
Synchronous Asynchronous
Connector DB50
Port standard and
operating mode
V.24
(EIA/TIA-23
2)
V.35 EIA/TIA-449, X.21 and
EIA-530
V.24 (EIA/TIA-232)
DTE, DCE DTE, DCE DTE DCE
Minimum baud
rate (bps)
1200 1200 1200 1200 300
Maximum baud
rate (bps)
64 K 2.048 M 2.048 M 2.048 M 115.2 K
Services DDN leased line
Terminal access
Backup
Modem dial-up
Backup