Associated Equipment 6009 Battery Charger User Manual


 
20.
GROUNDING AND AC POWER CORD CONNECTION INSTRUCTIONS
The charger should be grounded to reduce the risk of electric shock. This charger is equipped with an electric cord having an equipment
grounding conductor and a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance with
all local codes and ordinances.
DANGER. Never alter the AC cord or plug provided - if it will not fit
the outlet, have a proper outlet installed by a qualified electrician.
Improper connection can result in a risk of an electric shock. This
battery charger is for use on a nominal 120-volt circuit, and has a
grounding plug that looks like the plug illustrated in FIGURE (A). A
temporary adapter, which looks like the adapter illustrated in FIGURE
(C), may be used to connect this plug to a two-pole receptacle, as
shown in FIGURE (B), until a properly grounded outlet can be
installed by a qualified electrician.
GROUNDED
OUTLET
GROUNDING METHODS
GROUNDING
MEANS
ADAPTER
COVER OF GROUNDED
OUTLET BOX
(A) (B)
(C
ADAPTER
)
DANGER. Before using an adapter as illustrated, be certain that the center screw of the outlet plate is grounded. The green-colored rigid
ear or lug extending from the adapter must be connected to a properly grounded outlet - make certain it is grounded. If necessary, replace the
original outlet cover plate screw with a longer screw that will secure the adapter ear or lug to the outlet cover plate and make ground
connection to grounded outlet.
NOTE: USE OF AN ADAPTER IS NOT ALLOWED IN CANADA. IF A GROUNDING TYPE RECEPTACLE IS NOT AVAILABLE, DO NOT
USE THIS APPLIANCE UNTIL THE PROPER OUTLET IS INSTALLED BY A QUALIFIED ELECTRICIAN.
21.
LENGTH OF CHARGE
a. Test the battery for state of charge. Do not charge if it is over 75% charged or the battery is determined to be defective.
b. Set beginning amps charge rate for size of battery and state of charge per charts
c. Charge for length of time per charge,
d. Discontinue charge when the specific gravity of electrolyte reaches 1.260 or above. A temperature compensating hydrometer should be
used for this reading. Discontinue charge if the battery begins to gas excessively or when the temperature of the electrolyte reaches
approximately 120°F. Do not overcharge batteries. Overcharging results in excessive water loss and eventual damage to the battery.
23.6
11.8
5.9
1.110
23.8
11.9
5.95
1.140
24.2
12.1
6.05
1.185
24.8
12.4
6.2
1.225
25%50%75% DEAD
Open Circuit Voltage 24V
Open Circuit Voltage 12V
Open Circuit Voltage 6V
Specific Gravity
STATE OF CHARGE
STATE OF CHARGE TABLE
Cold Cranking Amps
Reserve Capacity
Ampere Hours
BATTERY SIZE
60
90
350
80+
100+
400+
40
60
275
BATTERY SIZE TABLE
LARGE
MEDIUM
SMALL
BATTERY SIZE %CHARGE
0-25
303030
454550
202020
303540
55
2025
15
25
20
35
55
15
25
45
10
20
30
20
40
55
15
30
50
10
20
30
30
60
90
25
45
70
15
30
45
15
15 15 15
10
10
10 10 10
15 30 45 60 75 90
MINUTES
A
M
P
E
R
E
S
SMALL MEDIUM LARGE
CHARGE RATE Vs. MINUTES CHARGE
25-50
50-75
50-75
25-50
0-25
50-75
25-50
0-25
ASSEMBLY INSTRUCTIONS
Attach the handle to the charger using the four screws provided.