Remove battery when it becomes fully charged
Charger output voltage must be turned down after battery is removed
At finish of charge, turn main power switch "Off" to conserve energy
When a battery is fully charged, it must be removed from the charging circuit. If it is not, it may be damaged by over charging.
END OF CHARGE:
Discontinue charge when three successive hydrometer readings taken at half hour intervals fail to show an increase in specific gravity, or when
battery begins to gas excessively or when temperature of electrolyte reaches approximately 120EF. If a battery is sealed and these determinations
cannot be made, see manufacturer's instructions for charging.
WIRING DIAGRAM
MODEL 6080A PARTS LIST
605675 - Switch w/knob (1)
610172 - Switch - Rocker
605616 - Ammeter
605206 - AC Cord
610098 - DC Cable set
610117 - Circuit Breaker
610090 - Rectifier
610088 - Transformer
610057 - Handle (optional accessory)
610072 - Side panels (1 pair)
610075 - Top panel
610076 - Base
610082 - Back panel
610083 - Front panel
6074 - Jumper leads (set of 5)