Banner P4 Stud Sensor User Manual


 
Banner Engineering Corp. • Minneapolis, MN USA
www.bannerengineering.com • Tel: 763.544.3164
Page 10
Vision Sensors
Correct Part Verification Application
Objective
:
Verify that the correct parts are
ejected from a feeder bowl. As
fasteners eject from the feeder
bowl, a correct fastener in any
orientation must be verified and an
incorrect fastener must be rejected.
Sensors/Components:
- P4 GEO P4GI
- 8 mm Lens LCF08
- LEDRA80X80M Visible Red
Area Light
- D10 Trigger Sensor
Operation:
The P4 GEO will verify the presence
of correct fasteners in any
orientation.
Configuration:
GEO Count tool/Test tool
Field of View: 1.0" x 0.8"
Working Distance: 3"