Page 6
Vision Sensors
360° Pattern Matching
PASS PASS FAIL
During Setup, the user identifies a section of
the image containing the target pattern in the
sensor’s field of view (FOV).
A template of the pattern is generated for the
GEO Count tool.
The template is stored in the sensor’s non-
volatile memory. (If the sensor power is cycled,
the inspection will be saved.)
The sensor searches
images to find the
template, regardless of orientation.
When inspected images contain matching
patterns, the inspected part will “PASS.”
When the
sensor does not
find a matching
image, the
inspected part
will “FAIL.”