Bosch Power Tools 1293D Sander User Manual


 
-12-
Service
Preventive maintenance
performed by unauthorized
per so n nel may result in misplacing of
internal wires and components which
could cause serious hazard. We
recommend that all tool service be performed
by a Bosch Factory Service Center or Autho -
rized Bosch Service Station.
TOOL LUBRICATION
Your Bosch tool has been properly lubricated
and is ready to use. It is recommended that
tools with gears be regreased with a special
gear lubricant at every brush change.
CARBON BRUSHES
The brushes and commutator in your tool
have been engineered for many hours of
dependable service. To maintain peak
efficiency of the motor, we recommend every
two to six months the brush es be examined.
Only genuine Bosch replace ment brushes
specially designed for your tool should be
used.
BEARINGS
After about 300-400 hours of operation, or at
every second brush change, the bearings
should be replaced at Bosch Factory Service
Center or Au thorized Bosch Service Station.
Bearings which become noisy (due to heavy
load or very abrasive material cut ting) should
be replaced at once to avoid overheating or
motor failure.
Cleaning
To avoid accidents always
dis connect the tool from the
power supply before cleaning or performing
any main tenance. The tool may be cleaned
most effectively with compressed dry air.
Always wear safety gog gles when cleaning
tools with compressed air.
Ventilation openings and switch levers must be
kept clean and free of foreign matter. Do not
at tempt to clean by inserting pointed objects
through openings.
Certain cleaning agents and
sol vents damage plastic
parts. Some of these are: gasoline, carbon
tetrachlo ride, chlo rinated cleaning solvents,
ammonia and house hold detergents that
contain ammonia.
!
WARNING
Maintenance
!
WARNING
!
CAUTION
If an extension cord is
necessary, a cord with
adequate size conductors that is capable
of carrying the current necessary for your
tool must be used. This will prevent
excessive voltage drop, loss of power or
overheating. Grounded tools must use 3-
wire extension cords that have 3-prong plugs
and receptacles.
NOTE: The smaller the gauge number, the
heav i er the cord.
RECOMMENDED SIZES OF EXTENSION CORDS
120 VOLT ALTERNATING CURRENT TOOLS
!
WARNING
Tool’s
Ampere
Rating
Cord Size in A.W.G.
Wire Sizes in mm
2
3-6
6-8
8-10
10-12
12-16
18 16 16 14 0.75 .075 1.5 2.5
18 16 14 12 0.75 1.0 2.5 4.0
18 16 14 12 0.75 1.0 2.5 4.0
16 16 14 12 1.0 2.5 4.0
14 12 —— ————
25 50 100 150 15 30 60 120
Cord Length in Feet Cord Length in Meters
Accessories
* Dust canister
* Sanding sheet
* Sandpaper punch-plate
** RS006 Vacuum hose adaptor
** VAC002 Vacuum hose adaptor
** Vacuum hoses
*standard equipment, **optional accessories
BM 2609932486 01-12:BM 2609932486 8-05 1/26/12 7:22 AM Page 12