4. Install existing or new brushes so the
curved surface of the brush end match-
es the curvature of the motor commuta-
tor (as seen through the brush opening).
NOTE: The detent on the brass clip must fit
into the slot on the side of the brush pocket,
which secures the brass clip in the proper
position (Figure C).
5. Reinstall brush covers by angling the
non-clip end into the opening. Make cer-
tain brush spring is centered in the “V”
notch on the brush, then snap closed
the clip end of the brush cover.
6. Plug power cord into a wall outlet. Run
the rotary tool at full speed for 5 minutes
under no load. This will properly seat the
brushes and extend the life of the tool.
For questions or replacement brushes,
please call Dremel’s Consumer Service
at
1-800-437-3635
or check our website at www.Dremel.com.
Cleaning The Tool
Ventilation openings and switch levers must
be kept clean and free of foreign matter. Do
not attempt to clean by inserting pointed
objects through openings.
The tool may be
cleaned with com-
pressed air. Always
wear safety goggles
when cleaning tool
with compressed air.
There is no need to lubricate the Dremel™
rotary tool.
Certain cleaning agents
and solvents will damage
plastic parts. Some of these are: gasoline,
carbon tetrachloride, chlorinated clean-
ing solvents, ammonia and household
detergents that contain ammonia.
Clean the “soft grip” areas of the tool using a
damp cloth. Tougher soiled areas may
require more than one wipe application to get
clean.