Briggs & Stratton 074000 Air Compressor User Manual


 
SPECIFICATIONS / MAINTENANCE
11
PRODUCT SPECIFICATIONS
MAINTENANCE
To ensure efficient operation and longer life of the air
compressor, prepare and follow a routine maintenance
schedule.The routine described in this section is intended for
an air compressor used under normal daily working
conditions. If necessary, modify the schedule to suit the
conditions under which you use your compressor.
Modifications will depend upon hours of operation and
working environment. Operating air compressors in
extremely dirty or hostile environments will require more
frequent maintenance checks.
NOTE: See FEATURES AND CONTROLS and OPERATION
for control locations.
Follow the hourly or calendar intervals, whichever occurs
first:
Maintenance
Schedule
Service Intervals
Service Dates
Fill in as you complete
regular service
Maintenance Task Daily Weekly
Every 50 Hours
or Yearly
Every 100 Hours
or Yearly
Inspect Safety Valve X
Inspect Fittings/Valves X
Inspect Oil Level X
Clean Unit X
Inspect and Clean Air
Filter
X
Inspect Pump Oil X*
Inspect Intake and
Exhaust Valves
X**
Inspect Safety Labels X***
* Change oil after first 100 hours of operation, then every 300 hours thereafter
** Return unit to approved repair center annual for inspection and service
*** Inspect annually, replace as necessary
AC Frequency: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60Hz
Rated AC Voltage: . . . . . . . . . . . . . . . . . 120 Volts, single phase
Running Horsepower: . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2 HP
Pump Type: . . . . . . . . . . . . . . . . . . Oil Lubricated Direct Drive
Lubricant:. . . . . . . . . . . . . . . . . . . . . . . . . SAE 5W50 Synthetic
Oil Capacity: . . . . . . . . . . . . . . . . . . . . . . . . . 7.168 oz. (200ml)
Air Delivery:
At 40 psi. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.9 CFM
At 90 psi. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.6 CFM
Cut-In Pressure Setting: . . . . . . . . . . . . . . . . . 80 psi (5.6 bars)
Cut/Out Pressure Setting: . . . . . . . . . . . . . . 125 PSI (8.7 bars)
Tank capacity: . . . . . . . . . . . . . . . . . . . . . . . . 6 Gallons (22.5 L)
Tank Style: . . . . . . . . . . . . . . . . . . . . . . . . Flat, single (Pancake)
Recommended Air Hose Size: . . . . . . . . . 3/8 inch ID (14mm)
Air Fittings: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4 inch NPT
Quick Connect Fitting Type: . . . . . . . . . . . . . . . . . . . . . . . . I/M
Operating Temperature Range: . . . 32
°
to 95
°
F (0
°
to+35
°
C)
Shipping Weight:. . . . . . . . . . . . . . . . . . . . . . . . 60lbs. (27.3 Kg)