Charging Tips
To Prevent Damage to Spotlight and Battery:
• Do not attempt to use spotlight while charging directly from AC
outlet. Doing so may cause damage to battery and AC charger.
• 12-volt DC charger/adapter operates from a cigarette lighter
receptacle for charging battery in spotlight only while vehicle engine
is running or continuous corded operation with or without battery.
• Do not attempt to charge battery pack using both AC an DC chargers
at the same time.
• Only use charging devices that are provided with the Q-Beam Blue Max
Rechargeable Spotlight or its replacements.
• For DC Charger/Adapter - Battery charges only while vehicle engine is
running.
For AC Charger - Allow battery to fully charge. L.E.D. indicator on
battery will automatically turn off when battery is fully charged.
See chart for recommended charge times.
• Do not allow battery to completely discharge. A dim light indicates a
low battery. Recharge battery as soon as possible after each use.
• Always keep the battery fully charged when not in use.
10
46810
20
DC Charge
AC Charge
USAGE (Minutes)
CHARGE TIME (Hours)
Charge Times
Charge times are dependent on usage of the
product. See chart below for recommended charge times.
6
To Replace Cigarette
Lighter Plug Fuse
Lighter Plug
Lighter Cap
Lighter Plug
Lighter Plug
Lighter Cap
Fuse
Fuse Holder
Lighter Cap
Lighter Cap
Step 1: Disconnect spot/flood light from power source.
Step 2: Unscrew cap of lighter plug and pull straight away from fuse.
Step 3: Pull fuse holder and fuse out of lighter plug. Observe to see if
fuse is burned out.
NOTE: Use a 8A fuse only. Fuse is burned out when fuse element is
missing or broken inside glass tube. Replace with new 8A fuse
if fuse element is missing or broken.
Step 4: Pull fuse out of fuse holder. Insert new fuse into holder.
Step 5: Insert fuse holder and fuse into lighter plug.
Step 6: Screw cap onto lighter plug.