SERVICE (Cont.)
EMI Filter (Models FPG & FPG-2)
FIG 60 EMI FILTER
FIG 61 EMI FILTER TERMINALS
Location:
The EMI Filter is located inside the rear cover of the
grinder housing.
Test Procedure:
1. Disconnect the dispenser from the power source.
2. Disconnect the two red wires and two white wires on
the EMI Filter from the EMI Filter wiring harness.
3. Check for resistance between the two red leads on
the EMI Filter. (Fig 61)
If resistance is present as described the EMI Filter is
operating properly.
If resistance is not present as described, replace the
EMI Filter.
Removal and Replacement:
1. Disconnect the wires from the EMI Filter.
2. Remove the two screws securing the EMI Filter.
3. Remove and discard EMI Filter.
4. Install new EMI Filter using two screws to secure
EMI Filter to its former location.
5. Refer to schematic when reconnecting the wires.
118.0 kΩ - 118.5 kΩ
Across either pair
GRINDER DBC
®