NAIL PLACEMENT LASER POINTER
The tool is equipped with a laser mounted near the nose. Turn the electronics switch
to the ON position. When the Work Contact Element (WCE) touches the workpiece and
slightly moves, the laser will shine on the spot where the nail will be driven. This can
be seen through the wide slots in the WCE and / or no-mar tip. When the laser is in the
desired location, simply fully press in the WCE and fire the tool.
This is a Class IIIA Laser Product that emits laser radiation.
Do not stare into beam or view directly with optical instruments.
NOTE: The laser will only show accurate placement when the depth control is set to
maximum depth.
FIRING THE NAILER
1. Load fasteners (see Loading / Unloading the Nailer section).
2. Connect the air supply to the nailer.
An improperly functioning tool must not be used. Do not actuate
the tool unless the tool is placed firmly against the work piece.
In Sequential Mode
Press the conversion switch to the “ ” side to activate Sequential Mode.
1. Slightly depress Work Contact element (WCE) against work surface.
2. Laser pointer will shine on spot where nail will be driven when the WCE slightly
touches the work surface.
3. Fully depress WCE.
4. Pull trigger. Fastener will be driven into workpiece.
In Bump Mode (Laser should not be used in Bump Mode)
Press the conversion switch to the “
” side to activate Bump Mode.
1. Remove tool from work surface. DO NOT point tool at yourself or others.
2. Pull trigger.
3. Firmly depress Work Contact element (WCE) against work surface. Tool will cycle.
4. Remove tool from work surface. Move tool to the next area where fastener is to be
driven and repeat.
LOW NAIL INDICATOR LIGHTS (See Figure 20)
The tool is equipped with lights on either side of the tool near the nose. Turn the
electronics switch to the ON position. When the nail count becomes 10 or so nails
remaining in the magazine, the lights will come on yellow. You may reload at that time
(See Loading the Nailer section). When the nail count becomes 5 or so remaining nails,
the Anti-Dry Fire will engage and the lights will turn red. You MUST reload at that time.
BUBBLE LEVEL (See Figure 21)
The tool is equipped with a bubble level located on the head cap. When the gun is in a
horizontal driving orientation, a level condition can easily be observed and controlled
by simply aligning the tool in such a manner whereas the bubble is between the center
markings on the length of the level. The same is true when in a vertically downward
driving orientation by aligning the tool such that the bubble is centered in the circular
marking at the top of the level.
Operation
CHN70600
Figure 21 - Bubble Level
Figure 19 - Laser Pointer
Figure 20 - Low Nail Indicator Lights