Campbell Hausfeld SN268K00 Staple Gun User Manual


 
22 Sp
Grapas
Estas grapas para acabado de Campbell Hausfeld los puede comprar en su tienda más cercana. Si necesita ayuda para
encontrar un artículo, comuníquese al 1-800-543-6400. Las grapas de Campbell Hausfeld cumplen o exceden las
especificaciones Federales FF-N-105B.
Información de intercambio
Las grapas usadas con la grapadora para acabado SN268K de Campbell Hausfeld también se pueden usar con las grapadoras :
Senco LN4450, SJS-LR, SKS L11-15, Hitachi N3804A, Duofast BN-1832S, KN-1848, ST-18, Stan-Tech SDS 18-14, Atro Minor 90/30,
90/32, 90/40, y Porter Cable NS100.
Calibre Fusión de Grapas Grapas
Modelo # Longitud de la grapa Corona Punta Acabado la linea por linea por caja
FN180615AV 12,7mm (1/2”) Calibre 18 6,4mm(1/4") Cincel Galvanizado/Cubierta por vinilo Adhesivo 100 1000
FN180620AV 19,1mm (3/4”) Calibre 18 6,4mm(1/4") Cincel Galvanizado/Cubierta por vinilo Adhesivo 100 1000
FN180625AV 25,4mm (1”) Calibre 18 6,4mm(1/4") Cincel Galvanizado/Cubierta por vinilo Adhesivo 100 1000
Servicio Técnico
Si desea hacer alguna pregunta refe-
rente a la reparación u operación de las
herramientas, o para solicitar copias
adicionales de este manual, sírvase
llamar a nuestro número especial,
1-800-543-6400.
Sujetadores y Piezas de
Repuesto
Use
solamente sujetadores Campbell
Hausfeld originales calibre 16 (o su
equivalente) - (vea la información
sobre intercambio de sujetadores). El
desempeño de las herramientas, la
seguridad y la duración pueden
disminuir si no se utilizan los
sujetadores adecuados. Cuando ordene
piezas de repuesto o sujetadores,
especifique el número de la pieza.
Para reparar la herramienta
La herramienta debe ser reparada
únicamente por personal calificado, y
deben usar piezas de repuesto y
accesorios originales Campbell
Hausfeld, o piezas y accesorios que
funcionen de manera equivalente.
Para colocarle los sellos
Cada vez que repare una grapadora
deberá limpiarle y lubricarle las partes
internas. Le recomendamos que use
Parker O-lube o un lubricante
equivalente en todos los anillos en O. A
cada anillo en O se le debe dar un baño
de lubricante para anillos antes de
instalarlos. Igualmente, deberá ponerle
un poco de aceite a todas las piezas
que se mueven y muñones. Finalmente,
después de haberla ensamblado y antes
de probar la herramienta deberá
ponerle unas cuantas gotas de aceite
sin detergente 30W u otro aceite
similar, en las líneas de aire.
Manual de Instrucciones
Notas
The work
surface
can become damaged by excessive
lubrication. Proper lubrication is the
owner’s responsibility. Failure to
lubricate the stapler properly will
dramatically shorten the life of the
stapler and void your warranty.
1. Disconnect the
air supply from
the stapler to
add lubricant.
2. Turn the stapler so
the air inlet is fac-
ing up. Place 4-5
drops of 30 W non-
detergent oil into
air inlet. Do not use
detergent oils, oil
additives, or air tool
oils. Air tool oils
contain solvents which will damage
the stapler's internal components.
3. After adding oil,
run stapler
briefly. Wipe off
any excess oil
from the cap
exhaust.
RECOMMENDED HOOKUP
The illustration below shows the
recommended hookup for the stapler.
1. The air com-
pressor must
be able to
maintain a
minimum of
60 psi when
the stapler is being used. An inade-
quate air supply can cause a loss of
power and inconsistent driving.
2. An oiler can be used
to provide oil
circulation through
the stapler. A filter
can be used to
remove liquid and
solid impurities which
can rust or “gum up” internal parts
of the stapler.
3
General Safety
Information (Continued)
Do not point the tool toward your-
self or anyone whether it contains
fasteners or not. Accidental trigger-
ing of the tool could result in death
or serious personal injury.
Do not drive a fas-
tener on top of
other fasteners. The
fastener could
glance and cause
death or a serious
puncture wound.
Do not operate
or allow anyone
else to operate
the tool if any
warnings or
warning labels
are not legible.
Warnings or warning labels are locat-
ed on the tool magazine and body.
Do not drop or throw the tool.
Dropping or throwing the tool can
result in damage that will make the
tool unusable or unsafe. If the tool
has been dropped or thrown, exam-
ine the tool closely for bent, cracked
or broken parts and air leaks. STOP
and repair before using or serious
injury could occur.
Caution
indicates
a potentially hazardous situation
which, if not avoided, MAY result in
minor or moderate injury.
Do not make any modifications to the
tool without first obtaining written
approval from Campbell Hausfeld. Do
not use the tool if any shields or
guards are removed or altered. Do
not use the tool as a hammer.
Personal injury or tool
damage may occur.
Always check that the Work Contact
Element (WCE) is operating proper-
ly. A fastener could accidentally be
driven if the WCE is not working
properly. Personal injury may occur
(See "Checking the Work Contact
Element" Section).
Disconnect air supply and release
tension from the pusher before
attempting to clear jams because
tools can be ejected from the front
of the tool. Personal injury may
occur.
Notice
indicates
important information, that if not
followed, MAY cause damage to
equipment.
Avoid using the tool when the mag-
azine is empty. Accelerated wear on
the tool may occur.
Clean and check all air supply hoses
and fittings before connecting the
tool to an air supply. Replace any
damaged or worn hoses or fittings.
Tool performance or durability may
be reduced.
Air compressors providing air to the
tool should follow the requirements
established by the American
National Standards Institute
Standard B19.3-1991; Safety
Standard for Compressors for
Process Industries. Contact your air
compressor manufacturer for
information.
Operating The
Stapler
Read this manual and understand
all safety warnings and instruc-
tions before operating the stapler.
LUBRICATION
This stapler requires lubrication before
using the stapler for the first time and
before each use. If an inline oiler is
used, manual lubrication through the
air inlet is not required on a daily basis.
Model SN268K00
60 psi
Min.
OIL
100 psi
Max.
Recommended Hookup
Quick
Coupler
Air Hose
Quick Plug
(Optional)
Quick
Coupler
(Optional)
Oiler
Regulator
Filter
Quick
Plug
www.chpower.com
O I L
!
WARNING