Central Pneumatic Air Compressor 94734 Air Compressor User Manual


 
SKU 94734 For technical questions, please call 1-800-444-3353. Page 5
Use eye and ear protection. 3. Always wear ANSI-approved safety impact eye gog-
gles, and ear plugs when using the Air Compressor.
Make sure all tools and equipment used with the Air Compressor are rated to 4.
the appropriate air pressure capacity of the Air Compressor. Do not use any
tool or equipment that does not operate from 0-120 PSI. If necessary, check the
owner’s manual of the tool or equipment for its air pressure rating.
Always disconnect the Air Compressor from its electrical outlet, release any 5.
remaining air pressure from the unit, and disconnect all pneumatic tools and
equipment from the unit, before performing any services or maintenance, or
when not in use.
Avoid injury. Never direct the air jet at people or animals.6.
Inspect safety valve daily7. . If the safety valve is not working properly, tank pressure
can build up to dangerous levels. The tank could explode. For this reason, pull the
ring on the safety valve before each use and verify that it operates freely. Replace
safety valve if it does not operate freely.
Never remove or alter the factory sealed Safety Release Valve.
Do not attempt to readjust the automatic start and shutoff valves. 8. Any change
to the automatic ON/OFF pressure levels will cause additional stress on the motor,
which may result in shortened motor life.
Drain the Air Compressor’s air tank every day. 9. Do not allow moisture to build up
inside the Air Tank.
Do not unscrew the tank drain valve so that 10. more than four threads are show-
ing.
Avoid risk of tank explosion11. .
Avoid weakening of tank by draining condensation after each use.a.
Never modify tank by drilling holes, welding to it, or modifying it’s parts.b.
The tank is designed, and factory set, to operate within a specic pressure range. c.
For that reason, never make adjustments to, or substitute parts, to the compres-
sor.
Avoid bodily injury from moving parts12. . The compressor cycles on automatically,
without notice. For this reason, always keep hands and arms away from compressor
parts when the unit is connected to electrical power. Always have compressor safety
guards in place before turning compressor on.
Use approved air hose13. . Never use plastic or PVC pipe (unless specied for Air
Compressors) to carry air under pressure. Regardless of its pressure rating, it can
burst under pressure.
Never plug the power cord of this product into an electrical outlet while stand-14.
ing on a wet or damp surface.
REV 07b