Central Pneumatic Air Compressor 99637 Staple Gun User Manual


 
SKU 99637 For technical questions, please call 1-800-444-3353. Page 12
depressed, gently and briey squeeze
the Trigger (39) once. One staple and
plastic cap will be red.
8. Do not press the Bottom Plate (95)
against the workpiece with excessive
force. Allow the tool to do the work.
Always allow the tool to recoil off the
work surface.
9. If the Stapler requires more force to
accomplish the task, verify that the
tool receives sufcient, unobstructed
airow ( 6 CFM) and increase the
pressure (70 to 90 PSI) output of
the regulator up to the maximum air
pressure rating of this tool.
CAUTION! TO PREVENT TOOL
AND ACCESSORY FAILURE,
RESULTING IN INJURY:
Do not exceed the tool’s maximum
air pressure rating (90 PSI).
If the Stapler still does not have
sufcient force at maximum pressure
and sufcient airow, then a larger
Stapler may be required.
10. To prevent accidents, turn off the
Stapler, detach the air supply, safely
discharge any residual air pressure
in the tool, and release the Trigger
(39) to its off position after use. Clean
external surfaces of the Stapler with
clean, dry cloth, and apply a thin coat
of tool oil. Then store the tool indoors
out of children’s reach.
MAINTENANCE
INSTRUCTIONS
Procedures not specically
explained in this manual must
be performed only by a qualied
technician.
TO PREVENT
SERIOUS INJURY
FROM ACCIDENTAL
OPERATION:
Turn off the Stapler, detach
the air supply, safely
discharge any residual air
pressure in the tool, and turn
the Trigger (39) to its off
position before performing
any inspection, maintenance,
or cleaning procedures.
TO PREVENT SERIOUS
INJURY FROM TOOL
FAILURE:
Do not use damaged
equipment. If abnormal
noise, vibration, or leaking
air occurs, have the problem
corrected before further use.
TO PREVENT EXPLOSION:
Lubricate the Stapler only
with specied lubricants.
Lubricate the air inlet
using only pneumatic tool
oil. Lubricate the internal
mechanism using only
white lithium grease. Other
lubricants may damage the
mechanism and may be
highly ammable, causing an
explosion.
Note: These procedures are in addition to
the regular checks and maintenance
explained as part of the regular op-
eration of the air-operated tool.
1. Daily:
Every day, perform maintenance on
the air supply according to the com-
ponent manufacturers’ instructions.
The lubricator’s oil level needs to
be maintained and the moisture
REV 08k